IP138A SERIES
IP138A SERIES
IP338A SERIES
IP338A SERIES
LM138 SERIES
Parameter
V
REF
Reference Voltage
Test Conditions
I
OUT
= 10mA
I
OUT
= 10mA to 5A
V
IN
– V
OUT
= 3V to 35V
P
£
50W
T
J
= –55 to +150°C
Min.
1.238
1.225
IP138A
Typ.
1.25
1.250
0.005
0.020
5
0.1
20
0.3
0.002
Max.
1.262
1.270
0.010
0.040
15
0.3
30
0.6
0.010
Min.
LM138
IP138
Typ.
Max. Units
V
1.190
1.240
0.005
0.020
5
0.1
20
0.3
0.002
60
1.290
0.010
0.040
15
0.3
30
0.6
0.010
V
D
V
OUT
Line Regulation
1
D
V
IN
D
V
OUT
Load Regulation
1
D
I
OUT
Thermal Regulation
V
IN
– V
OUT
= 3V to 35V
T
J
= –55 to +150°C
I
OUT
= 10mA to 5A
I
OUT
= 10mA to 5A
T
J
= –55 to +150°C
t
p
= 20ms
C
ADJ
= 0
V
OUT
= 10V
f = 120Hz
T
J
= –55 to +150°C
I
OUT
= 10mA to 5A
V
IN
– V
OUT
= 3V to 35V
T
J
= –55 to +150°C
V
IN
– V
OUT
= 35V
T
J
= –55 to +150°C
V
IN
– V
OUT
£
10V
DC
0.5ms Peak
5
7
0.25
T
J
= –55 to +150°C
V
IN
– V
OUT
= 30V
T
J
= –55 to +150°C
C
ADJ
= 10
m
F
T
J
= –55 to +150°C
60
V
OUT
£
5V
V
OUT
³
5V
V
OUT
£
5V
V
OUT
³
5V
%/V
mV
%
mV
%
%/W
dB
dB
60
75
45
0.2
100
5
60
Ripple Rejection
75
45
0.2
100
5
I
ADJ
Adjust Pin Current
m
A
m
A
mA
A
A
%
D
I
ADJ
Adjust Pin Current
Change
I
MIN
Minimum Load
Current
I
SC
Current Limit
3.5
8
12
1
1
t = 1000 Hrs
0.3
0.001
5
5
7
3.5
8
12
1
5
D
V
OUT
Temperature
D
TEMP Stability
D
V
OUT
Long Term Stability
D
TIME
e
n
R
q
JC
RMS Output Noise
(% of V
OUT
)
Thermal Resistance
Junction to Case
T
J
= –55 to +150°C
T
A
= 125°C
f = 10 Hz to 10 kHz
K Package (TO–3)
2
1
1
0.3
0.001
1
%
%
1
1
°C/W
1) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to
heating effects are covered under thermal regulation specifications. Load regulation is measured from the bottom of the package
for the TO–3 package.
2) Test Conditions unless othewise stated: V
IN
– V
OUT
= 5V , T
J
= 25°C , I
OUT
= 2.5A.
Although power dissipation is internally limited, these specifications apply for dissipations of 50W and I
MAX
= 5A.