B15
Typical Performance Characteristics
FLOW CHARACTERISTICS
8
7
INLET PRESSURE 10 bar
ELEMENT 40 MICROMETRE
6
5
4
3
2
1
0
0
50
100
150
200
250
AIR FLOW - dm3/s
Standard Redimount Filter-Regulators
Automatic Drain, 40 m element, 8 bar spring
Type
Port Size
G3/4
Relieving
Weight kg
3,16
Non-relieving
B15-698-F3LD
B15-898-F3LD
B15-A98-F3LD
B15-B98-F3LD
Weight kg
3,16
B15-696-F3LD
B15-896-F3LD
B15-A96-F3LD
B15-B96-F3LD
G1
3,12
3,12
Metal bowl
G11/4
G11/2
3,14
3,14
3,18
3,18
Manual Drain, 40 m element, 8 bar spring
Type
Port Size
G3/4
Relieving
Weight kg
3,01
Non-relieving
B15-698-B3LD
B15-898-B3LD
B15-A98-B3LD
B15-B98-B3LD
Weight kg
3,01
B15-696-B3LD
B15-896-B3LD
B15-A96-B3LD
B15-B96-B3LD
G1
2,95
2,95
Metal bowl
G11/4
G11/2
2,99
2,99
3,03
3,03
Non-standard Models
For replacement Filter-Regulators, substitute ‘0’ and ‘O’ at the 4th and 10th digits respectively, e.g. B15-096-F3LO. Supplied without Unidaptors as
replacement units or for the build-up of Combination Units. Please consult our Technical Service for further details.
For optional 5 m or 25 m elements, substitute ‘1’ or ‘2’ respectively for ‘3’ at the 8th digit, e.g. B15-696-F1LD.
For optional 4 or 16 bar springs, substitute ‘F’ or ‘S’ respectively for ‘L’ at the 9th digit, e.g. B15-696-F3FD. (16 bar spring only available with T-bar adjusting
screw).
For optional T-bar adjusting screw, substitute ‘A’ for ‘B’ at the 1st digit, e.g. A15-696-F3LD.
Specify if unit is required complete with T15 Shut-Off Valve fitted upstream. For details of Shut-Off Valves, see page 8.11.021.01.
For other options, please consult our Technical Service.
Accessories
Wall Mounting Bracket Kit, see page 8.7.041.03.
Pressure Gauges, see page 8.11.031.01.
8.7.041.02