316L SS Pressure Sensor
PERFORMANCE SPECIFICATIONS
Model 86 UltraStable
All parameters specified at 1.5mA and at 25°C, after 10 second warm up, unless otherwise indicated. Unless specifically indicated, only those parameters
indicated as tested are verified on each part. Parameters are specified for the compensated version only.
PARAMETERS
Full Scale Output Span
Zero Pressure Output (Offset)
Pressure Non Linearity
Pressure Hysteresis
Repeatability
Input Resistance
Output Resistance
Temperature Error - Span (–20 to +85°C)
Temperature Error - Offset (–20 to +85°C)
Thermal Hysteresis - Span
Thermal Hysteresis - Offset
Long Term Stability - Span
Long Term Stability - Offset
Supply Current
Output Load Resistance
Insulation Resistance (50 VDC)
Pressure Overload
Compensated Temperature Range
Operating Temperature Range
Storage Temperature Range
Media - Pressure Port
Media - Reference Port
Weight
–20°C to +85°C
–40°C to +125°C
–50°C to +125°C
Liquids and Gases compatible with 316L Stainless Steel
Compatible with Silicon, Pyrex, Gold, Fluorosilicone Rubber and
316L Stainless Steel
13 g
0.5
5
50
3X
2000
4000
–0.75
–0.5
0.05
0.05
0.1
0.1
1.5
2.0
MIN
75
–1
–0.10
–0.05
0.02
0.02
3500
4500
25000
+0.75
+0.5
TYP
100
0
MAX
150
1
0.10
+0.05
UNITS
mV
mV
±% Span
±% Span
±% Span
NOTES
1
2
3
% Span
% Span
% Span
% Span
±% Span/year
±% Span/year
mA
M
M
Rated
9
9
9
6
7
8
4
4, 5
4
4
Notes
1. For amplified output circuits see application note TN-003.
2.
3.
4.
5.
Measured at vacuum for absolute (A), ambient for gage (G).
Best fit straight line.
Over the temperature range –20°C to +85°C with respect to +25°C.
15 psi range sensors have an offset temperature error of ±0.75%
(Max) from –20°C to +85°C.
6.
7.
8.
9.
Guarantees output/input ratiometricity.
Load resistance to reduce measurement errors due to output loading.
Between case and sensing element.
Maximum temperature range for product with standard cable and
connector is –20°C to +105°C.
10. For gage units used at pressures below atmosphere, the span accuracy
is not guaranteed.
ORDERING INFORMATION
6
APPLICATION SCHEMATIC
CONNECTIONS
PAD/CONDUCTOR NO
1
2
3
4
5
6
FUNCTION
+OUT
-EX
+EX
-OUT
GAIN
GAIN
Feel free to contact customer service with any questions at
Toll free 1(800)745-8008; Phone (757)766-1500; Fax (757)766-4297
June 2001
ISO – Wide Temperature Range
1-71