Miniature Relay P1
Coil data
Nominal voltages
Nominal power consumption
monostable with 1 winding
bistable with 2 windings
bistable with 1 winding
Operative range/pick-up class according to IEC 255-1-00
and VDE 0435 Part 201
Maximum operate voltage
Maximum release voltage (bistable)
Minimum release voltage (monostable)
From 1.5 V– to 24 V–
65 ... 130 mW
65 ... 150 mW
30 ... 130 mW
1/a
75 % of nominal voltage
75 % of nominal voltage
10 % of nominal voltage
U
I
U
II
= Minimum voltage at 20 °C after pre-energizing
with nominal voltage without contact current
= Maximum continuous voltage at 20 °C
The operating voltage limits
U
I
and
U
II
are dependent on the
temperature according to the formulae:
U
I tamb
=
k
I
·
U
I 20 °C
and
U
II tamb
= k
II
·
U
II 20 °C
t
amb
=
U
I tamb
=
U
II tamb
=
k
I
a.
k
II
=
Ambient temperature
Minimum voltage at ambient temperature
t
amb
Maximum voltage at ambient temperature
t
amb
Factors (dependent on temperature), see diagram
Ambient temperature
t
amb
[°C]
Siemens AG