欢迎访问ic37.com |
会员登录 免费注册
发布采购

MIL-STD-461E 参数 Datasheet PDF下载

MIL-STD-461E图片预览
型号: MIL-STD-461E
PDF下载: 下载PDF文件 查看货源
内容描述: 2A EMI滤波模块 [2A EMI Filter Module]
分类和应用:
文件页数/大小: 10 页 / 236 K
品牌: ETC [ ETC ]
 浏览型号MIL-STD-461E的Datasheet PDF文件第2页浏览型号MIL-STD-461E的Datasheet PDF文件第3页浏览型号MIL-STD-461E的Datasheet PDF文件第4页浏览型号MIL-STD-461E的Datasheet PDF文件第5页浏览型号MIL-STD-461E的Datasheet PDF文件第6页浏览型号MIL-STD-461E的Datasheet PDF文件第7页浏览型号MIL-STD-461E的Datasheet PDF文件第8页浏览型号MIL-STD-461E的Datasheet PDF文件第9页  
MIL-STD-461 EMI INPUT FILTER
FGDS-2A-50V up to 2A CURRENT
Hi-Rel
Hi-Rel
Grade
Grade
2A EMI Filter Module
9 to 50 VDC Input Range
MIL-STD-461C/D/E Compliant
• To comply with MIL-STD-461D/E power leads :
• CE 102 : Emission requirement over 10KHz to 10MHz
• CS 101 : Susceptibility requirement over 30Hz to 150KHz
• CS 114 : Susceptibility requirement over 10KHz to 400MHz
• CS 115 : Susceptibility requirement for spikes
• To comply with MIL-STD-461C power leads :
• CE 03 : Emission requirement over 15KHz to 50MHz
• CS 01 : Susceptibility requirement over 30Hz to 50KHz
• CS 02 : Susceptibility requirement over 15KHz to 400MHz
• CS 06 : Susceptibility requirement for spikes
• To comply with DO-160C/D/E power lines :
• Conducted emission requirement over 15KHz to 30MHz
• Conducted susceptibility requirement over 10KHz to 400MHz
• Susceptibility requirement for induced transients
• Temperature range :
• operating temperature : -40°C/+105°C case
• storage temperature : -55°C/+125°C
The GAIA Converter filter module FGDS-2A-50V
provides a state-of-the-art product to fulfill
Electromagnetic Interferences (EMI) requirements
for Aerospace/Defence applications.
The FGDS-2A-50V complies with major standards
including :
the US MIL-STD-461 rev C, rev D and rev E
the international DO-160 rev C, rev D and rev E
In particular, the filter module is compliant with
the following requirements of MIL-STD-461C/D/E
standards :
MIL-STD-461D/E Part 2. & 3. requirements :
Conducted Emission (CE)
CE102, power leads, emission over
10KHz to 10MHz, basic curve
Conducted Susceptibility (CS)
CS101, power leads, frequency 30Hz
to 150KHz, curve #1
CS114, bulk cable injection, frequency
10KHz to 400MHz,
CS115, spikes, bulk cable injection,
calibrated spike
DO-160-C/D/E requirements :
Conducted Emission (CE)
Section 21 power lines, emission over
15KHz to 30MHz, category B, AZ & LMH
Conducted Susceptibility (CS)
Section 20 power lines, frequency 10KHz
to 400MHz
In addition, this filter withstands in a transparent
state without dammage the transient and spike
requirements of :
MIL-STD-704A with 80V/100ms & 600V/10µs
MIL-STD-1275B with 100V/50ms & 250V/70µs
The FGDS-2A-50V is suitable for all GAIA
Converter DC/DC converters and architecture
from 4W up to 50W power
up to 2A input current
up to 50V permanent input voltage.
1-General
MIL-STD-461C Part 2. & 3. requirements :
Conducted Emission (CE)
CE03, power leads, emission over
15KHz to 50MHz, narrowband, Class A1
CE03, power leads, emission over
15KHz, broadband, Class A1 curve#
1&2
Conducted Susceptibility (CS)
CS01, power leads, frequency over 30Hz
to 50KHz, class A1, consult factory
for criteria
CS02, power leads, frequency 15KHz
to 400MHz, class A1
CS06, power leads, spike #1
6
2-Product Selection
FGDS-2A-50V (/T) and/or (/S)
(/T) : option for -55°C start up operating temperature.
(/S) : option for screening and serialization
REDEFINING THE SOURCE OF POWER
©
Gaia Converter FC05-050.03/08 Revision B
For locations, phone, fax, E-Mail see back cover