Hi-Rel  
Grade  
MGDM-04 Series  
11- Description of Protections  
Vo (%)  
11-1 Output Short Circuit Protection (SCP)  
100  
The short circuit protection device protects the module  
against short circuit of any duration and restores the mo-  
dule to normal operation when the short circuit is removed.  
It operates in «hiccup» mode by testing periodically if an  
overload is applied (typically every 200ms recovery time).  
The overload detection threshold is typically 200% of maxi-  
mum current with a detection time lower than 5ms.  
detection time  
x
time  
recovery time  
recovery time  
11-2 Output Overvoltage Protection (OVP)  
The output overvoltage protection device protects external  
components against high voltage or possible overvoltages  
which can be supplied by the module (i.e in case of internal  
failure). It consists of a zener diode clamping the output  
voltage; under worst case conditions this zener diode will  
short-circuit.  
The output voltage protection is not designed to withstand  
externally applied output overvoltages to protect the mo-  
dule itself.  
4
12- Description of Functions  
12-1 On/ Off Function  
The control pin 20 (On/ Off) can be used for applications  
requiring On/ Off operation. By using an open collector  
command with a transistor Q referenced to the common  
terminal (Gi) :  
On/ Off  
• A logic pulled low (<0.2V@1mA, referenced to Gi)  
on pin 20 disables the converter  
No connection or high impedance on pin 20 enables  
the converter.  
Command  
GI  
By releasing the On/Off function, the converter will restart  
within the start-up time specifications given in table page 3.  
For further details please consult ’Logic On/ Off’ Applica-  
tion Note.  
11  
Gaia Converter FC97-008.08/ 06 Revision N  
©
For locations, phone, fax, E-Mail see back cover  