74LCX125
DC Electrical Characteristics
Symbol
I
CC
∆I
CC
Parameter
Quiescent Supply Current
Increase in I
CC
per Input
(Continued)
V
CC
(V)
2.3
−
3.6
2.3
−
3.6
2.3
−
3.6
T
A
= −40°C
to
+85°C
Min
Max
10
±10
500
µA
µA
Conditions
V
I
=
V
CC
or GND
3.6V
≤
V
I
, V
O
≤
5.5V (Note 5)
V
IH
=
V
CC
−0.6V
Units
Note 5:
Outputs disabled or 3-STATE only.
AC Electrical Characteristics
T
A
= −40°C
to
+85°C,
R
L
=
500Ω
Symbol
Parameter
V
CC
=
3.3V
±
0.3V
C
L
=
50 pF
Min
t
PHL
t
PLH
t
PZL
t
PZH
t
PLZ
t
PHZ
t
OSHL
t
OSLH
Output to Output Skew (Note 6)
Output Disable Time
Output Enable Time
Propagation Delay
1.5
1.5
1.5
1.5
1.5
1.5
Max
6.0
6.0
7.0
7.0
6.0
6.0
1.0
1.0
1.5
1.5
1.5
1.5
1.5
1.5
V
CC
=
2.7V
C
L
=
50 pF
Min
Max
6.5
6.5
8.0
8.0
7.0
7.0
1.5
1.5
1.5
1.5
1.5
1.5
V
CC
=
2.5V
±
0.2V
C
L
=
30 pF
Min
Max
7.2
7.2
9.1
9.1
7.2
7.2
ns
ns
ns
ns
Units
Note 6:
Skew is defined as the absolute value of the difference between the actual propagation delay for any two separate outputs of the same device. The
specification applies to any outputs switching in the same direction, either HIGH-to-LOW (t
OSHL
) or LOW-to-HIGH (t
OSLH
).
Dynamic Switching Characteristics
Symbol
V
OLP
V
OLV
Parameter
Quiet Output Dynamic Peak V
OL
Quiet Output Dynamic Valley V
OL
Conditions
C
L
=
50 pF, V
IH
=
3.3V, V
IL
=
0V
C
L
=
30 pF, V
IH
=
2.5V, V
IL
=
0V
C
L
=
50 pF, V
IH
=
3.3V, V
IL
=
0V
C
L
=
30 pF, V
IH
=
2.5V, V
IL
=
0V
V
CC
(V)
3.3
2.5
3.3
2.5
T
A
=
25°C
Typical
0.8
0.6
−0.8
−0.6
Units
V
V
Capacitance
Symbol
C
IN
C
OUT
C
PD
Input Capacitance
Output Capacitance
Power Dissipation Capacitance
Parameter
Conditions
V
CC
=
Open, V
I
=
0V or V
CC
V
CC
=
3.3V, V
I
=
0V or V
CC
V
CC
=
3.3V, V
I
=
0V or V
CC
, f
=
10 MHz
Typical
7
8
25
Units
pF
pF
pF
3