Series CPV
Phase Control Modules
• 120 & 240 Vac Models
• 0-5 Vdc Phase Control
Models CPV120 and CPV240 auxiliary
function modules provide control of the
phased turn-on of a solid state relay, in
response to the application of a 0-5 Vdc
control signal. They must be used with
Crydom Series 1 (-10) random turn-on
solid state relays. Consult factory about
use with 480 Vac loads. For a com-
plete set (control module and solid state
relay) order 10CPV120, 25CPV120, etc.
Manufactured in Crydom’s ISO 9002
Certified facility for optimum product
performance and reliability.
MODEL NUMBERS
120 Vac
240 Vac
10CPV120
10CPV240
25CPV120
25CPV240
40CPV120
50CPV240
75CPV240
90CPV240
RELAY OUTPUT SPECIFICATIONS
Œ
Operating Voltage Range (47-63 Hz) [Vrms]
Load Current Range
Ž
[Arms]
Transient Overvoltage [Vpk]
Max. Surge Current, (16.6ms) [Apk]
Max. On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case [R
θJC
] °C/W
Maximum I2 t for Fusing, (8.3 msec.) [A2sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]

Max. Turn-On Time [msec]
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
90-140 (120 Vac Models)
180-280 (240 Vac Models)
.04-10
.04-25
.04-50
.04-75
.04-90
400 (120 Vac models)
600 (240 Vac models)
120
1.6
1.48
60
10.0
500
0.02
1
/
2
250
1.6
1.02
260
10.0
500
0.02
1
/
2
625
1.6
0.63
1620
10.0
500
0.02
1
/
2
1000
1.6
0.31
4150
10.0
500
0.02
1
/
2
1200
1.6
0.28
6000
10.0
500
0.02
1
/
2
cycle
0.5
cycle
0.5
cycle
0.5
cycle
0.5
cycle
0.5
CONTROL MODULE INPUT SPECIFICATIONS
Œ
Logic Supply Range (Terminal 3A)
Typical Supply Current
Control Voltage Range (Terminal 3B)
Nominal Control Input Impedance
Min. Turn-Off Voltage
DC CONTROL
3.5-10Vdc
1.6mA @ 5Vdc
0-5 Vdc
1500 Ohms
1.0
CONTROL MODULE OUTPUT (Terminal 4B – Input to Relay)
Œ
Max. Off-State Operating Voltage
Max. Load Current (Sink)
Max. On-State Voltage @ 3mA
Max. Off-State Leakage @ 10Vdc
36 Vdc
3.0 mA
0.5 Vdc
1.0 µAdc
©1998 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
Œ
All parameters at 25ºC unless otherwise specified.

Off-State dv/dt test method per
EIA/NARM standard RS-443,
paragraph 13.11.1
Ž
Heat sinking required (Relay Only),
see Series 1 data sheet.
FastFax Document No. 203
SERIES CPV.040898, PAGE 1 OF 2
For recommended applications and more information contact:
USA:
(800) 8 CRYDOM
(800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE:
http://www.crydom.com
FASTFAX Product Information:
(888) 267-9191
UK:
(44)1202 812300
fax (44)1202 812340
85, Condor Close, Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY:
(49)871 935405
fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany