 浏览型号HD6433846XXXH的Datasheet PDF文件第241页浏览型号HD6433846XXXH的Datasheet PDF文件第242页浏览型号HD6433846XXXH的Datasheet PDF文件第243页浏览型号HD6433846XXXH的Datasheet PDF文件第244页浏览型号HD6433846XXXH的Datasheet PDF文件第246页浏览型号HD6433846XXXH的Datasheet PDF文件第247页浏览型号HD6433846XXXH的Datasheet PDF文件第248页浏览型号HD6433846XXXH的Datasheet PDF文件第249页  
Table 9-15 Input Capture Input Signal Input Edges Due to Input Capture Input Pin  
Switching, and Conditions for Their Occurrence  
Input Capture Input  
Signal Input Edge  
Conditions  
Generation of rising edge  
When TMIG is modified from 0 to 1 while the TMIG pin is high  
When NCS is modified from 0 to 1 while the TMIG pin is high, then  
TMIG is modified from 0 to 1 before the signal is sampled five times by  
the noise canceler  
Generation of falling edge When TMIG is modified from 1 to 0 while the TMIG pin is high  
When NCS is modified from 0 to 1 while the TMIG pin is low, then  
TMIG is modified from 0 to 1 before the signal is sampled five times by  
the noise canceler  
When NCS is modified from 0 to 1 while the TMIG pin is high, then  
TMIG is modified from 1 to 0 after the signal is sampled five times by  
the noise canceler  
Note: When the P13 pin is not set as an input capture input pin, the timer G input capture input  
signal is low.  
Switching input capture input noise canceler function  
When performing noise canceler function switching by modifying NCS in port mode register 3  
(PMR3), which controls the input capture input noise canceler, TMIG should first be cleared to 0.  
Note that if NCS is modified without first clearing TMIG, an edge will be regarded as having been  
input at the pin even though no valid edge has actually been input. Input capture input signal input  
edges, and the conditions for their occurrence, are summarized in table 9-16.  
Table 9-16 Input Capture Input Signal Input Edges Due to Noise Canceler Function  
Switching, and Conditions for Their Occurrence  
Input Capture Input  
Signal Input Edge  
Conditions  
Generation of rising edge  
When the TMIG pin level is switched from low to high while TMIG is  
set to 1, then NCS is modified from 0 to 1 before the signal is sampled  
five times by the noise canceler  
Generation of falling edge When the TMIG pin level is switched from high to low while TMIG is  
set to 1, then NCS is modified from 1 to 0 before the signal is sampled  
five times by the noise canceler  
230  