 浏览型号Z8F1602AR020EC的Datasheet PDF文件第87页浏览型号Z8F1602AR020EC的Datasheet PDF文件第88页浏览型号Z8F1602AR020EC的Datasheet PDF文件第89页浏览型号Z8F1602AR020EC的Datasheet PDF文件第90页浏览型号Z8F1602AR020EC的Datasheet PDF文件第92页浏览型号Z8F1602AR020EC的Datasheet PDF文件第93页浏览型号Z8F1602AR020EC的Datasheet PDF文件第94页浏览型号Z8F1602AR020EC的Datasheet PDF文件第95页  
Z8F640x/Z8F480x/Z8F320x/Z8F240x/Z8F160x  
Z8 Encore!®  
73  
information on approximate time-out delays for the minimum and maximum WDT reload  
values.  
Table 45. Watch-Dog Timer Approximate Time-Out Delays  
Approximate Time-Out Delay  
WDT Reload Value  
WDT Reload Value  
(with 50kHz typical WDT oscillator frequency)  
(Hex)  
000004  
FFFFFF  
(Decimal)  
4
Typical  
80µs  
Description  
Minimum time-out delay  
Maximum time-out delay  
16,777,215  
335.5s  
Watch-Dog Timer Refresh  
When first enabled, the Watch-Dog Timer is loaded with the value in the Watch-Dog  
Timer Reload registers. The Watch-Dog Timer then counts down to 000000Hunless a  
WDT instruction is executed by the eZ8 CPU. Execution of the WDT instruction causes  
the downcounter to be reloaded with the WDT Reload value stored in the Watch-Dog  
Timer Reload registers. Counting resumes following the reload operation.\  
When the Z8F640x family device is operating in Debug Mode (via the On-Chip Debug-  
ger), the Watch-Dog Timer is continuously refreshed to prevent spurious Watch-Dog  
Timer time-outs.  
Watch-Dog Timer Time-Out Response  
The Watch-Dog Timer times out when the counter reaches 000000H. A time-out of the  
Watch-Dog Timer generates either an interrupt or a Short Reset. The WDT_RESOption Bit  
determines the time-out response of the Watch-Dog Timer. Refer to the Option Bits chap-  
ter for information regarding programming of the WDT_RESOption Bit.  
WDT Interrupt in Normal Operation  
If configured to generate an interrupt when a time-out occurs, the Watch-Dog Timer issues  
an interrupt request to the interrupt controller and sets the WDTstatus bit in the Watch-Dog  
Timer Control register. If interrupts are enabled, the eZ8 CPU responds to the interrupt  
request by fetching the Watch-Dog Timer interrupt vector and executing code from the  
vector address. After time-out and interrupt generation, the Watch-Dog Timer counter  
rolls over to its maximum value of FFFFFH and continues counting. The Watch-Dog  
Timer counter is not automatically returned to its Reload Value.  
WDT Interrupt in Stop Mode  
If configured to generate an interrupt when a time-out occurs and the Z8F640x family  
device is in STOP mode, the Watch-Dog Timer automatically initiates a STOP Mode  
Recovery and generates an interrupt request. Both the WDTstatus bit and the STOPbit in  
the Watch-Dog Timer Control register are set to 1 following WDT time-out in STOP  
PS017610-0404  
Watch-Dog Timer  