 浏览型号Z8F082ASH020SC的Datasheet PDF文件第76页浏览型号Z8F082ASH020SC的Datasheet PDF文件第77页浏览型号Z8F082ASH020SC的Datasheet PDF文件第78页浏览型号Z8F082ASH020SC的Datasheet PDF文件第79页浏览型号Z8F082ASH020SC的Datasheet PDF文件第81页浏览型号Z8F082ASH020SC的Datasheet PDF文件第82页浏览型号Z8F082ASH020SC的Datasheet PDF文件第83页浏览型号Z8F082ASH020SC的Datasheet PDF文件第84页  
Z8 Encore! XP® F08xA Series  
Product Specification  
62  
Select either the rising edge or falling edge of the Timer Input signal for the count.  
This selection also sets the initial logic level (High or Low) for the Timer Output  
alternate function. However, the Timer Output function is not required to be  
enabled.  
2. Write to the Timer High and Low Byte registers to set the starting count value. This  
only affects the first pass in COUNTER mode. After the first timer Reload in  
COUNTER mode, counting always begins at the reset value of 0001H. In COUNTER  
mode the Timer High and Low Byte registers must be written with the value 0001H.  
3. Write to the Timer Reload High and Low Byte registers to set the Reload value.  
4. If appropriate, enable the timer interrupt and set the timer interrupt priority by writing  
to the relevant interrupt registers.  
5. Configure the associated GPIO port pin for the Timer Input alternate function.  
6. If using the Timer Output function, configure the associated GPIO port pin for the  
Timer Output alternate function.  
7. Write to the Timer Control register to enable the timer.  
In COUNTER mode, the number of Timer Input transitions since the timer start is given  
by the following equation:  
Counter Mode Timer Input Transitions = Current Count Value Start Value  
COMPARATOR COUNTER Mode  
In COMPARATOR COUNTER mode, the timer counts input transitions from the analog  
comparator output. The TPOLbit in the Timer Control Register selects whether the count  
occurs on the rising edge or the falling edge of the comparator output signal. In COMPAR-  
ATOR COUNTER mode, the prescaler is disabled.  
The frequency of the comparator output signal must not exceed one-fourth the system  
clock frequency.  
Caution:  
After reaching the Reload value stored in the Timer Reload High and Low Byte registers,  
the timer generates an interrupt, the count value in the Timer High and Low Byte registers  
is reset to 0001Hand counting resumes. Also, if the Timer Output alternate function is  
enabled, the Timer Output pin changes state (from Low to High or from High to Low) at  
timer Reload.  
The steps for configuring a timer for COMPARATOR COUNTER mode and initiating the  
count are as follows:  
1. Write to the Timer Control register to:  
Disable the timer  
Configure the timer for COMPARATOR COUNTER mode  
PS024705-0405  
P R E L I M I N A R Y  
Timers  