 浏览型号Z0221524ASCR4508TR的Datasheet PDF文件第33页浏览型号Z0221524ASCR4508TR的Datasheet PDF文件第34页浏览型号Z0221524ASCR4508TR的Datasheet PDF文件第35页浏览型号Z0221524ASCR4508TR的Datasheet PDF文件第36页浏览型号Z0221524ASCR4508TR的Datasheet PDF文件第38页浏览型号Z0221524ASCR4508TR的Datasheet PDF文件第39页浏览型号Z0221524ASCR4508TR的Datasheet PDF文件第40页浏览型号Z0221524ASCR4508TR的Datasheet PDF文件第41页  
Z02215  
Single Chip Modem with Integrated Controller, Data Pump, and AFE  
31  
Table 3. AT Command Set (Continued)  
Function and Description  
Command  
R
Line  
Reversal  
Command  
When issued to the modem transmitting at 75 bps during Minitel V.23 operation  
(B4 and S register S37 is 1), this command causes the transmit data rate to  
change to 1200 bps and the receive data rate to change to 75 bps. If the remote  
and Option modem supports and is configured for Minitel operation with line reversals, it  
automatically detects the rate switch and changes its own transmit and receive  
data rates.  
When issued to modems in the IDLE state (no connection), this command  
causes the modem to attempt to establish its next connection using the reverse  
data band, as described below.  
The V.22bis, V.22, Bell 212, V.23, Bell 202, V.21 and Bell 103 data modes each  
support two data bands. One data band is used to transmit data, the other to  
receive. The modem picks which data bands it uses for transmit and receive  
according to whether it is the calling or answering modem for the connection. If  
the data bands are reversed, the modem will not be able to establish a  
connection with another modem unless that modem's data bands are also  
reversed.  
By issuing this command to both the calling and answering modems, a V.23  
Minitel connection (command B4) may be started with the calling modem  
transmitting at 1200 bps and receiving at 75 bps.  
This command may be used before establishing a connection in any data band,  
and affects only the next connection.  
If the modem is in the IDLE state, the R command configures the modem to  
enter STATIC REVERSE mode when a Minitel connection is made. If the  
modem has a connection and is in Minitel MASTER mode then issuing the R  
command performs a direct turnaround. If the reversal is successful then the  
modem returns OK. If the reversal is unsuccessful, the modem returns OK.  
Otherwise, it returns NO CARRIER. If the modem is not in MASTER mode,  
ERROR is returned.  
When B4 and S-register S37 are 1 and the terminal is transmitting at 75 bps  
during Minitel V.23 operation, the transmit and receive rates change to 1200  
bps and 75 bps respectively. If the remote modem supports and is configured  
for Minitel operation with line reversals, it automatically detects the rate switch  
and changes its own transmit and receive data rates. See “Minitel Line  
Reversal” on page 44 for details.  
Note: R may be followed the O command in the command line to return ON-  
LINE immediately.  