ELECTRICAL CHARACTERISTICS
Absolute Maximum Ratings
Stresses greater than those listed under Absolute Maximum Ratings can cause permanent device failure. Functionality at or
above these limits is not implied. Exposure to absolute maximum ratings for extended periods can affect device reliability.
Storage Temperature
V
CC
with respect to AGND/DGND
V
NEG
with respect to AGND/DGND
V
BAT2
V
BAT1
with respect to AGND/DGND:
Continuous
10 ms
BGND with respect to AGND/DGND:
A(TIP) or B(RING) to BGND:
Continuous
10 ms (F = 0.1 Hz)
1 µs (F = 0.1 Hz)
250 ns (F = 0.1 Hz)
Current from A (TIP) or B (RING)
RYOUT1, RYOUT2 current
RYOUT1, RYOUT2 voltage
RYOUT1, RYOUT2 transient
RYE voltage (relays off)
RYE voltage (relays on)
C3–C1, D2–D1, E1:
Input voltage
ESD Immunity (Human Body Model)
Maximum power dissipation, continuous,
T
A
= 85º C, No heat sink (see note)
In 32-pin PLCC package
Thermal data:
In 32-pin PLCC package
Note:
Thermal limiting circuitry on chip will shut down the circuit at a junction temperature of about 165° C. Operation above 145° C junction temperature
may degrade device reliability.
–55 to
+150º
C
0.4 to
+7
V
0.4 V to V
BAT2
V
BAT1
to GND
+0.4
to –104 V
+0.4
to –109 V
+3
to –3 V
V
BAT1
–5 to
+1
V
V
BAT1
–10 to
+5
V
V
BAT1
–15 to
+8
V
V
BAT1
–20 to
+12
V
±150 mA
75 mA
RYE to
+7
V
RYE to
+10
V
BGND to V
BAT1
BGND to –90 V
–0.4 V to V
CC
+
0.4 V
1500 V min
1.33 W
θ
JA
45º C/W typ
Thermal Resistance
The junction to air thermal resistance of the Le79R101 device in a 32-pin PLCC package is 45° C/W. The typical junction to case
thermal resistance is 14° C/W. Measured under free air convection conditions and without external heat-sinking.
Electrical Operating Ranges
Legerity guarantees the performance of this device over commercial (0
°
to 70
°
C) and industrial (−40
°
to 85
°
C) temperature
ranges by conducting electrical characterization over each range, and by conducting a production test with single insertion
coupled to periodic sampling. These characterization and test procedures comply with section 4.6.2 of Bellcore TR-TSY-000357
Component Reliability Assurance Requirements for Telecommunications Equipment.
Environmental Ranges
Ambient Temperature
Ambient Relative Humidity
0° to 70°C Commercial
–40° to +85 °C extended temperature
15 to 85%
6
Le79R101 Data Sheet