Le75181
Table 2. Ring Return Switch, 3
Parameter
OFF-state Leakage
Current (SW3):
+25 °C
+85 °C
–40 °C
dc Current Limit
ON-resistance
ON-state Voltage*
Isolation:
+25 °C
+85 °C
–40 °C
dV/dt Sensitivity
†
Vswitch (both poles) = ±320 V, Logic inputs = Gnd
Vswitch (both poles) = ±330 V, Logic inputs = Gnd
Vswitch (both poles) = ±310 V, Logic inputs = Gnd
—
Iswitch
Iswitch
Iswitch
—
—
—
—
—
—
—
—
200
Test Condition
Measure
Min
Typ
Data Sheet
Max
Unit
Vswitch (differential) = –320 V to Gnd
Vswitch (differential) = –60 V to +260 V
Vswitch (differential) = –330 V to Gnd
Vswitch (differential) = –60 V to +270 V
Vswitch (differential) = –310 V to Gnd
Vswitch (differential) = –60 V to +250 V
Vswitch (on) = ±10 V
Iswitch (on) = 0 mA, ±10 mA
Iswitch = I
LIMIT
@ 50 Hz/60 Hz
Iswitch
Iswitch
Iswitch
Iswitch
∆
V
ON
V
ON
—
—
—
—
—
—
—
—
—
200
—
—
1
µA
1
1
—
100
130
1
1
1
—
mA
Ω
V
µA
V/µs
*This parameter is not tested in production. Choice of secondary protector should ensure this rating is not exceeded.
†Applied voltage is 100 Vp-p square wave at 100 Hz. Not tested in production.
Table 3. Ringing Access Switch, 4
Parameter
OFF-state Leakage
Current (SW3):
+25 °C
+85 °C
–40 °C
ON-resistance
ON Voltage
Ring Generator Current
During Ring
Steady-state Current
†
Surge Current
†
Release Current
Isolation:
+25 °C
+85 °C
–40 °C
dV/dt Sensitivity
‡
Vswitch (both poles) = ±320 V, Logic inputs = Gnd
Vswitch (both poles) = ±330 V, Logic inputs = Gnd
Vswitch (both poles) = ±310 V, Logic inputs = Gnd
—
Iswitch
Iswitch
Iswitch
—
—
—
—
—
—
—
—
200
1
1
1
—
µA
Vswitch (differential) = –255 V to +210 V
Vswitch (differential) = +255 V to –210 V
Vswitch (differential) = –270 V to +210 V
Vswitch (differential) = +270 V to –210 V
Vswitch (differential) = –245 V to +210 V
Vswitch (differential) = +245 V to –210 V
Iswitch (on) = ±70 mA, ±80 mA
Iswitch (on) = ± 1 mA
V
CC
= 5 V
INPUT = 1
—
—
—
∆
V
ON
—
I
RINGSOURCE
—
—
—
—
—
—
—
—
—
—
—
2
—
—
500
12
3
—
150
2
—
Ω
V
mA
mA
A
µA
Iswitch
Iswitch
Iswitch
—
—
—
—
—
—
1
µA
1
1
Test Condition
Measure
Min
Typ
Max
Unit
V/µs
*This parameter is not tested in production. Choice of secondary protector should ensure this rating is not exceeded.
†Applied voltage is 100 Vp-p square wave at 100 Hz. Not tested in production.
7