 浏览型号AGRL8583DAJ-DT的Datasheet PDF文件第9页浏览型号AGRL8583DAJ-DT的Datasheet PDF文件第10页浏览型号AGRL8583DAJ-DT的Datasheet PDF文件第11页浏览型号AGRL8583DAJ-DT的Datasheet PDF文件第12页浏览型号AGRL8583DAJ-DT的Datasheet PDF文件第14页浏览型号AGRL8583DAJ-DT的Datasheet PDF文件第15页浏览型号AGRL8583DAJ-DT的Datasheet PDF文件第16页浏览型号AGRL8583DAJ-DT的Datasheet PDF文件第17页  
Data Sheet  
L8583D Line Card Access Switch  
October 2002  
Temperature Shutdown Mechanism  
Protection  
When the device temperature reaches a minimum of  
110 °C, the thermal shutdown mechanism will activate  
and force the device into an all-off state, regardless of  
the logic input pins. Pin TSD, when used as an output,  
will read 0 V when the device is in the thermal shut-  
down mode and +VDD during normal operation.  
Integrated SLIC Protection  
Diode Bridge  
In the L8583D, protection to the SLIC device or other  
subsequent circuitry is provided by a combination of  
current-limited break switches, a diode bridge clamping  
circuit, and a thermal shutdown mechanism.  
During a lightning event, due to the relatively short  
duration, the thermal shutdown will not typically acti-  
vate.  
During a positive lightning event, fault current is  
reduced by the dynamic current-limit circuit and  
directed to ground via the diode bridge. Voltage is  
clamped to a diode drop above ground. Negative light-  
ning is again reduced by the dynamic current limit and  
directed to battery via the diode bridge.  
During an extended power cross, the device tempera-  
ture will rise and cause the device to enter the thermal  
shutdown mode. This forces an all-off mode, and the  
current seen at TBAT/RBAT drops to zero. Once in the  
thermal shutdown mode, the device will cool and exit  
the thermal shutdown mode, thus re-entering the state  
it was in prior to thermal shutdown. Current, limited to  
the dc current-limit value, will again begin to flow and  
device heating will begin again. This cycle of entering  
and exiting thermal shutdown will last as long as the  
power-cross fault is present. The frequency of entering  
and exiting thermal shutdown will depend on the mag-  
nitude of the power cross. If the magnitude of the  
power cross is great enough, the external secondary  
protector may trigger shunting all current to ground.  
For power cross and power induction faults, the posi-  
tive cycle of the fault is clamped a diode drop above  
ground and fault currents steered to ground and the  
negative cycle of the power cross is steered to battery.  
Fault currents are limited by the current-limit circuit.  
Current Limiting  
During a lightning event, the current that is passed  
through the break switches and presented to the inte-  
grated protection circuit and subsequent circuitry is lim-  
ited by the dynamic current-limit response of the break  
switches (assuming idle/talk state). When the voltage  
seen at the TLINE/RLINE nodes is properly clamped by  
an external secondary protector, upon application of a  
1000 V, 10 x 1000 pulse (LSSGR lightning), the current  
seen at the TBAT/RBAT nodes will typically be a pulse of  
magnitude 2.5 A and duration less than 0.5 µs.  
In the L8583D, the thermal shutdown mechanism can  
be disabled by forcing the TSD pin to +VDD. This func-  
tionality is different from the L7581, whose thermal  
shutdown mechanism cannot be disabled.  
Electrical specifications relating to the integrated over-  
voltage clamping circuit are outlined in Table 15.  
During a power-cross event, the current that is passed  
through the break switches and presented to the inte-  
grated protection circuit and subsequent circuitry is lim-  
ited by the dc current-limit response of the break  
switches (assuming idle/talk state). The dc current limit  
is specified over temperature between 80 mA and  
250 mA. Note that the current-limit circuitry has a nega-  
tive temperature coefficient. Thus, if the device is sub-  
jected to an extended power cross, the value of current  
seen at TBAT/RBAT will decrease as the device heats  
due to the fault current. If sufficient heating occurs, the  
temperature shutdown mechanism will activate and the  
device will enter an all-off mode.  
13  