O U TP U T VO LTAG E & C U R R EN T R ATIN G S - 5 0 & 1 0 0 W ATT M O D ELS
C P M
Output
Power
50 W
50 W
50 W
Input
Voltage
Output
Voltage(2)
5 V
Output
Current
10.0 A
10.0 A
4.2 A
4.2 A
2.1 A
20.0 A
20.0 A
8.5 A
Regulation
Ripple &
Noise(1)
Efficiency
Model
Number
Line
Load
88-370 VDC(3)
36-72 VDC
88-370 VDC(3)
36-72 VDC
88-370 VDC(3)
88-370 VDC(3)
36-72 VDC
88-370 VDC(3)
36-72 VDC
88-370 VDC(3)
20 mV
20 mV
48 mV
48 mV
96 mV
20 mV
20 mV
48 mV
48 mV
96 mV
40 mV
40 mV
100 mV
100 mV
150 mV
40 mV
40 mV
100 mV
100 mV
150 mV
150 mV
150 mV
200 mV
200 mV
200 mV
150 mV
150 mV
200 mV
200 mV
200 mV
82%
80%
82%
82%
82%
82%
80%
82%
82%
82%
CPM50FS05
CPM5048S05
CPM50FS12
CPM5048S12
CPM50FS24
CPM100FS05
CPM10048S05
CPM100FS12
CPM10048S12
CPM100FS24
5 V
12 V
12 V
24 V
5 V
50 W
50 W
100 W
100 W
100 W
100 W
100 W
5 V
12 V
12 V
24 V
8.5 A
4.2 A
No te s
1. Measured with 220 µF capacitor at the output at 20 MHz bandwidth (0 °C to +85 °C).
2. Fixed (TRM pin open) ±10% adjustable by external VR.
3. 85-264 VAC with the CPH500 - See CPH Series.
•
M e c h a n ic a l D e ta ils & Ap p lic a tio n N o te s - 5 0 & 1 0 0 Wa tt M o d e ls
Pin Connection
Function
1
2
3
DC IN +
DC IN +
DC IN -
RC
Positive Input Voltage
1 & 2 are internally connected
Negative Input Voltage
4
Remote Control
5
6
7
8
TRM
+S
Ext. Adjustment of Output Voltage
+ Remote Sensing Terminal
Positive Output Voltage
7 & 8 are internally connected
Negative Output Voltage
9 & 10 are internally connected
- Remote Sensing Terminal
Current Balance Terminals for
Parallel Operation
DC OUT +
DC OUT +
DC OUT -
DC OUT -
-S
9
10
11
12
CB
(CPM100)
NOTES:
1. All dimensions in mm tolerance ±0.3 mm.
2. Dimensions in brackets - CPM50.
3. Weight CPM50 = 120 g, CPM100 = 150 g
OUTPUT VOLTAGE ADJ.
CPM50 EXTERNALLY MOUNTED PARTS
CPM100 EXTERNALLY MOUNTED PARTS
Output
Voltage
Value of externally
Output
Voltage
Value of externally
mounted resistors (Ω)
mounted resistors (Ω)
VR
R1
0Ω
R2
VR
R1
R2
5
1 K
1 K
1 K
0Ω
0Ω
0Ω
5
1 K
2 K
5 K
110
180
240
390
12
24
820
12
24
2.4 K
11 K
2.4 K
Remote Control
The remote control circuit is controlled by using the RC and -ve DC IN
terminals - example circuit shown opposite.
1. Between RC and -ve DC IN - terminals: “Low” level or short
circuited (0-1.2 V) - Output: ON.
2. Between RC and -ve DC IN - terminals: “High” level or open
circuited (2.4-5.5 V) - Output: OFF.
3. Output current from the RC terminal is 1 mA typical when the
voltage at the RC terminal is at low level.
Short-circuit the RC and -ve DC IN - terminal to disable
remote control.
w w w .xp p lc .c o m
s a le s @xp p lc .c o m