O U TP U T VO LTAG E & C U R R EN T R ATIN G S - 5 0 & 1 0 0 W ATT M O D ELS  
C P M  
Output  
Power  
50 W  
50 W  
50 W  
Input  
Voltage  
Output  
Voltage(2)  
5 V  
Output  
Current  
10.0 A  
10.0 A  
4.2 A  
4.2 A  
2.1 A  
20.0 A  
20.0 A  
8.5 A  
Regulation  
Ripple &  
Noise(1)  
Efficiency  
Model  
Number  
Line  
Load  
88-370 VDC(3)  
36-72 VDC  
88-370 VDC(3)  
36-72 VDC  
88-370 VDC(3)  
88-370 VDC(3)  
36-72 VDC  
88-370 VDC(3)  
36-72 VDC  
88-370 VDC(3)  
20 mV  
20 mV  
48 mV  
48 mV  
96 mV  
20 mV  
20 mV  
48 mV  
48 mV  
96 mV  
40 mV  
40 mV  
100 mV  
100 mV  
150 mV  
40 mV  
40 mV  
100 mV  
100 mV  
150 mV  
150 mV  
150 mV  
200 mV  
200 mV  
200 mV  
150 mV  
150 mV  
200 mV  
200 mV  
200 mV  
82%  
80%  
82%  
82%  
82%  
82%  
80%  
82%  
82%  
82%  
CPM50FS05  
CPM5048S05  
CPM50FS12  
CPM5048S12  
CPM50FS24  
CPM100FS05  
CPM10048S05  
CPM100FS12  
CPM10048S12  
CPM100FS24  
5 V  
12 V  
12 V  
24 V  
5 V  
50 W  
50 W  
100 W  
100 W  
100 W  
100 W  
100 W  
5 V  
12 V  
12 V  
24 V  
8.5 A  
4.2 A  
No te s  
1. Measured with 220 µF capacitor at the output at 20 MHz bandwidth (0 °C to +85 °C).  
2. Fixed (TRM pin open) ±10% adjustable by external VR.  
3. 85-264 VAC with the CPH500 - See CPH Series.  
M e c h a n ic a l D e ta ils & Ap p lic a tio n N o te s - 5 0 & 1 0 0 Wa tt M o d e ls  
Pin Connection  
Function  
1
2
3
DC IN +  
DC IN +  
DC IN -  
RC  
Positive Input Voltage  
1 & 2 are internally connected  
Negative Input Voltage  
4
Remote Control  
5
6
7
8
TRM  
+S  
Ext. Adjustment of Output Voltage  
+ Remote Sensing Terminal  
Positive Output Voltage  
7 & 8 are internally connected  
Negative Output Voltage  
9 & 10 are internally connected  
- Remote Sensing Terminal  
Current Balance Terminals for  
Parallel Operation  
DC OUT +  
DC OUT +  
DC OUT -  
DC OUT -  
-S  
9
10  
11  
12  
CB  
(CPM100)  
NOTES:  
1. All dimensions in mm tolerance ±0.3 mm.  
2. Dimensions in brackets - CPM50.  
3. Weight CPM50 = 120 g, CPM100 = 150 g  
OUTPUT VOLTAGE ADJ.  
CPM50 EXTERNALLY MOUNTED PARTS  
CPM100 EXTERNALLY MOUNTED PARTS  
Output  
Voltage  
Value of externally  
Output  
Voltage  
Value of externally  
mounted resistors ()  
mounted resistors ()  
VR  
R1  
0Ω  
R2  
VR  
R1  
R2  
5
1 K  
1 K  
1 K  
0Ω  
0Ω  
0Ω  
5
1 K  
2 K  
5 K  
110  
180  
240  
390  
12  
24  
820  
12  
24  
2.4 K  
11 K  
2.4 K  
Remote Control  
The remote control circuit is controlled by using the RC and -ve DC IN  
terminals - example circuit shown opposite.  
1. Between RC and -ve DC IN - terminals: Low” level or short  
circuited (0-1.2 V) - Output: ON.  
2. Between RC and -ve DC IN - terminals: High” level or open  
circuited (2.4-5.5 V) - Output: OFF.  
3. Output current from the RC terminal is 1 mA typical when the  
voltage at the RC terminal is at low level.  
Short-circuit the RC and -ve DC IN - terminal to disable  
remote control.  
w w w .xp p lc .c o m  
s a le s @xp p lc .c o m  
 复制成功!