Mechanical Details 1000 Watts
NOTE: ‘-F’ option (24 V models only) increases the overall height from 75 to 106 mm.
Weight 2.5 kg
SYMBOL
VB
CB
+V
+V
-V
-V
FG
N
L
PIN CONNECTIONS
FUNCTION
Voltage Balance
Current Balance
Output Terminal (+)
Output Terminal (+)
Output Terminal (-)
Output Terminal (-)
Frame Ground
AC (N)
AC(L)
SCREW
M3
M4
PIN
1
2
3-8
9
10
11-12
13
14
OPTIONAL CN3 PIN CONNECTIONS
FUNCTION
SYMBOL
ROF + (-R)
RC+
ROF - (-R)
RC-
N/C
NC
LV Alarm (-W)
LV+
LV Alarm Ground (-W)
LV-
N/C
NC
PF Alarm + (-W)
PF+
PF Alarm Ground (-W)
PF-
Connector
CN3 S148B-PHDSS
Mating Connector
PHDR-14VS
Terminal
Mfr
Chain: SPHD-002T-P.0.5
Loose: BPHD-001T-P0.5 J.S.T
BPHD-002T-P0.5
For mating loom kit for optional CN3 order
part number “CPK CN3 LOOM”
Average 21 A max per pin for TB1
Forced Air Cooling (60 CFM)
The temperature points A and B shown are marked
on the psu chassis.
• Point A must be
60°C and point B must be
≤65°C
at Ta = 50°C.
• Point A must be
80°C and point B must be
80°C at Ta = 70°C.
The confirmation of the temperatures of point A and
B is not necessary if option fan “-F” is used.
Load factor is dependent on input
voltage and is an average power figure.
(See part number table).
Convection Cooled - Derating Curves
Convection Cooled
CPK 750
Installation Method
Note: 1. Output ripple & noise may be outside specification.
2. Load factor dependent on input voltage (see part number table) and is an average power figure.
CPK 600