AC-DC PCB Mount
5-10 Watts
CPF Series
•
T
HE
XP
ERTS
I
N
P
OWER
PCB Mounting
•
Low Cost
•
Universal Input
•
Small Footprint
•
Rugged Design
•
Surface Mount Technology
•
Accessory Mounting Boards
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
•
•
•
•
85-264 VAC (110-370 VDC)
47-440 Hz
0.3 A max (110 VAC Io = 100%)
15 A typical (110 VAC Io = 100%),
30 A typical (230 VAC = Io 100%)
at cold start
0.5 mA max at 230 VAC 60 Hz
General
Efficiency
Isolation
•
•
See Table
3000 VAC Input to Output
2000 VAC Input to Ground
500 VAC Output to Ground
100 kHz typical
Switching Frequency •
Earth Leakage
Current
•
Environmental
Operating
Temperature
Storage
Temperature
Humidity
Shock
Vibration
•
•
•
•
•
-10 °C to +55 °C (derate linearly above
+55 °C to 25% at +70 °C)
-20 °C to +75 °C
20-95% RH non-condensing
20 G 11 ms once each X, Y & Z axis
2 G 10-55 Hz 3 min period for 60 mins
along X, Y & Z axis
Output
Output Voltage
Minimum Load
Start-Up Delay
Hold-Up Time
Initial Set Accuracy
Drift
Line Regulation
Load Regulation
Ripple & Noise
Overvoltage
Protection
Overcurrent
Protection
Temperature
Coefficient
•
•
•
•
•
•
•
•
•
•
•
•
See Table
No minimum load required
700 ms max at rated input & load
10 ms min
-3%, +6% max
0.6% max
See Table
See Table
260 mV pk-pk max, 20 MHz bandwidth
Operates >115% Vnom, clamps by
zener diode
Operates >125% of rating,
auto recovery
0.04%/°C
EMC & Safety
Emissions
ESD Susceptibility
Radiated
Susceptibility
EFT/Burst
Surge
Safety Approvals
•
•
•
•
•
•
EN55022 Level B conducted
EN55022 Level B radiated
EN61000-4-2 Level 3 Air,
Level 2 Contact
EN61000-4-3 Level 3
EN61000-4-4 Level 3
EN61000-4-5 Level 3 line to line,
Level 4 line to ground
UL1950, C-UL, EN60950, VDE 0160
•
•
www.xpplc.com
sales@xpplc.com