AC-DC Chassis Mount
400-650 Watts
CPB600 Series
T
HE
XP
ERTS
I
N
P
OWER
Universal PFC Input
Low Profile (61mm)
Wide Output Voltage Adjustment
Remote ON/OFF
Power Good Signal
Remote Sense
Peak Current Available
Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage
Current
95-264 VAC (120-370 VDC)
47-63 Hz
8.2 A max at 115 VAC
40 A max at 230 VAC
0.98/0.95 at 115/230 VAC
0.75 mA max at 230 VAC 60 Hz
Remote ON/OFF
12 V 3 mA applied between RCG &
RC2 will inhibit the output of the unit
& the fan
General
Efficiency
Isolation
See Table
3000 VAC Input to Output
2000 VAC Input to Ground
500 VAC Output to Ground
130kHz PFC, 330 kHz PWM
Output
Output Voltage
Output Voltage
Adjustment
Minimum Load
Start-Up Time
Hold-up Time
Drift
Line Regulation
Load Regulation
Ripple & Noise
Overvoltage
Protection
Overload Protection
See Table
See Table
No minimum load required
400 ms typical at 230 VAC, 100% load
20 ms typical at 100% load
±0.4% max
±0.5% max
±1.0% max 0-100% load
± 1% max pk-pk 20 MHz bandwidth
110-130% of Vnom
Recycle input to reset
Operates at 105% of rated current
(101% of pk rating), <5 s auto recovery
>5 s recycle input to reset
±1.25% max -20 °C to +50 °C
Operates in the event of fan failure
or if the operating temperature/
derating criteria is exceeded
Compensates for 0.3 V drop max
If not required sense terminals
must be connected locally
ie: +S to +M and -S to -M on CN1
Switching Frequency •
Environmental
Operating
Temperature
Storage
Temperature
Relative Humidity
Shock
Vibration
-20 °C to +70 °C, derate linearly above
+50 °C to 50% at +70°C
-20 °C to +75 °C
20-90% non condensing
20 G 11 ms, once each x, y and z axis
2 G 10-55Hz for 3 min periods for
60 min along each x, y and z axis
EMC & Safety
Emissions
ESD
Susceptibility
Radiated
Susceptibility
EFT/Burst
Surge
Safety Approvals
EN55022 Level B conducted
EN55022 Level A radiated
EN61000-4-2 Level 2 contact,
Level 3 air
EN61000-4-3 Level 3
EN61000-4-4 Level 3
EN61000-4-5 Level 3 line to line
Level 4 line to ground
UL60950, C-UL (CSA 60950) EN60950
Temperature
Coefficient
Overtemperature
Protection
Remote Sense
www.xpplc.com