Specification
Input
Input Voltage
Input Frequency
Input Current
Inrush Current
Power Factor
Earth Leakage Current
85-264 VAC (120-370 VDC)
47-63 Hz
19 A at 115 VAC
40 A at 230 VAC
0.98/0.95 at 115/230 VAC
1.5 mA max at 230 VAC/60Hz
General
Efficiency
Isolation
• See tables
• 3000 VAC Input to Output
2000 VAC Input to Ground
500 VAC Output to Ground
• 130 kHz PFC, 200 kHz PWM
Switching Frequency
Environmental
Operating Temperature
• -20 ºC to +70 ºC, derate linearly from
+50 ºC to 50% at +70 ºC
Relative Humidity
• 20-90% non-condensing
Storage Temperature
• -20 ºC to +75 ºC
Shock
• 20 G 11 ms, once each x, y and z axis
Vibration
• 2 G, 10 Hz to 55 kHz, 3 min periods for 60
min along each x, y and z axis
Output
Output Voltage
Output Voltage Trim
Minimum Load
Start Up Time
Hold Up Time
Drift
Line Regulation
Load Regulation
Ripple & Noise
Overvoltage Protection
Overtemperature
Protection
Overload Protection
See tables
See tables
No minimum load required
400 ms typical at 230 VAC, 100% load
20 ms typical at 100% load
±0.4% max
±0.5% max
±1.0% max 0-100% load
±1.0% pk-pk, 20MHz BW
110-130% Vnom, recycle input to reset
Operates in the event of fan failure or if
the operating temperature / derating
criteria is exceeded
• Operates at 105% of rated current (101%
of pk rating), <5 s auto recovery,
>5 s recycle input to reset
• ±1.25% max -20 ºC to +50 ºC
• Compensates for up to 0.3 V drop max
if not required, sense teminals must be
connected locally i.e +S to +M and
-S to -M on CN1
• 12 V 3 mA applied between RCG &
RC2 will inhibit the output of the unit
and the fan
EMC & Safety
Emissions
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Safety Approvals
• EN55022, level B conducted
EN55022, level A radiated
• EN61000-4-2, level 2 contact, level 3 air
• EN61000-4-3, level 3
• EN61000-4-4, level 3
• EN61000-4-5, level 3 line to line,
level 4 line to ground
• EN60950, UL60950, cUL (CSA 60950)
Temperature
Coefficient
Remote Sense
Remote On/Off