AC-DC Power Supplies  
CCL400 Series  
Signals & Controls  
Characteristic  
Notes & Conditions  
Uncomitted opto isolated transistor, normally off when AC is good (see fig.5)  
Provides 5 - 15ms warning of loss of output from AC failure off when AC is healthy.  
Uncommited isolated optocoupler diode, powered diode inhibits the supply (see fig.6 & 7)  
5V/0.5A Isolated supply present when AC applied.  
Power Fail (AC-OK)  
Inhibit  
Standby Supply  
Remote Sense  
Compensates for 0.25V per lead, 0.5V total drop.  
Power Fail  
Inhibit (High)  
Inhibit (Low)  
Figure 7  
Figure 5  
Figure 6  
5 V  
5 V  
POWER SUPPLY  
8V Max 3 mA  
POWER SUPPLY  
POWER SUPPLY  
Pin 6 CON 4  
Power Fail  
Collector  
1K  
5 mA 8 V Max  
1K  
Inhibit Hi  
8 V Max  
Pin 8 CON 4  
Inhibit Hi  
Pin 8  
Transistor On: Input & Output Not OK  
Transistor Off: Input & Output OK  
CON 4  
Power Fail  
Emitter  
Pin 5 CON 4  
Inhibit Lo  
Inhibit Lo  
5 mA  
Pin 3 CON 4  
Pin 3 CON 4  
VI RTN  
VI RTN  
Signal Connector  
Pin 7 CON 4  
Pin 7 CON 4  
Signal Connector  
Signal Connector  
Environmental  
Characteristic  
Minimum  
-40  
Typical  
Maximum  
+70  
Units  
°C  
Notes & Conditions  
See derating curve, fig.8. and Thermal  
Operating Temperature  
Storage Temperature  
Cooling  
Considerations on page 8.  
-40  
+85  
°C  
Convection or conduction-cooled with 0.5 °C/W or  
better heatsink  
Humidity  
Operating Altitude  
Shock  
95  
5000  
%RH  
m
Non-condensing  
3 x 30g shocks in each plane, total 18 shocks. 30g = 11ms ( 0.5msec), half sine. Conforms to EN60068-2-27 & EN60068-2-47  
Single axis 10 - 500 Hz at 2g sweep and endurance at resonance in all 3 planes. Conforms to EN60068-2-6  
Vibration  
Temperature Derating Curve  
400  
300  
200  
Conduction-cooled  
90 - 264 VAC  
Figure 8 - No Cover Fitted  
Convection-cooled 100 - 264 VAC  
&
Conduction-cooled 90 - 264 VAC  
176 W  
100  
0
-40 -30 -20 -10  
0
10 20 30 40 50 60 70  
Ambient Temperature (°C)  
Figure 9 - Cover Fitted  
400  
Conduction-cooled 90 - 264 VAC  
Convection-cooled 90 - 264 VAC  
322  
300  
201 W  
161 W  
200  
100  
0
-40 -30 -20 -10  
0
10 20 30 40 50 60 70  
Ambient Temperature (°C)  
www.xppower.com  