AC-DC Power Supplies
ALM65 Series
EMC: Immunity
Phenomenon
Standard
Test Level
Criteria
Notes & Conditions
ESD
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
3
A
A
A
A
A
15 kV air/ 8 kV contact
80-2700 MHz. IEC60601-1-2 Ed.4 at other frequencies
Radiated
EFT/Burst
Surge
Conducted
Magnetic Fields
10 V/m
3
Installation Class 3
10 V
4
A
Dip: 30% 500 ms
Dip: 60% 200 ms
Dip: 80% 5000 ms
Dip: 100% 5000 ms
Dip: 30% 25 AC Cycles
Dip: 60% 5 AC Cycles
Dip: 100% 0.5 AC Cycles
Int.: >95% 5000 ms
A/B
A/B
B
B
A
A
A
B
High Line/Low Line
High Line/Low Line
EN61000-4-11
Dips and Interruptions
230 VAC 100% load, 100 VAC 75%
230 VAC 100% load, 100 VAC 20%
At 8 angles
EN60601-1-2
Safety Approvals
Safety Agency
Safety Standard
UL60950-1 2nd Edition
EN60950-1
Notes & Conditions
UL
TUV
CB
Information Technology
IEC60950-1
CE
LVD
UL
ANSI/AAMI ES 60601-1
CSA C22.2 No. 60601
EN60601-1
CSA
TUV
CB
Medical
IEC60601-1
Others
CCC, PSE, KC & RCM
May require additional importer information
Mechanical Details
Class I
IEC 320-C14
4.941 (125.5)
35.433 0.8 (900 20)
1.512
(38.4)
ø 0.685
(17.4)
1.319 (33.5)
2.185 (55.5)
Optional Input Connector Retention (-A)
1.40 (35.7)
1.969 0.394 (50 10)
Class II
IEC 320-C8
0.177 (4.50)
0.374 0.012 (9.50 0.30)
1.319 (33.5)
0.039 (1.0)
RETURN ( - )
4.488 (114.0)
1.732 (44.0)
OUTPUT ( + )
Notes
1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except
output cable length.
5. For UK mains lead order part UK-MAINS-IEC for C14 versions, or UK-MAINS-8
for C8 versions.
2. Output connector: 5.5 outer diameter, 2.5 mm inner diameter with centre positive. 6. For US mains lead order part US-MAINS-IEC for C14 versions, or US-MAINS-8
3. Weight: 0.68 lbs (308 g) approx.
for C8 versions.
4. For European mains lead order part EU-MAINS-IEC for C14 versions,
or EU-MAINS-8 for C8 versions.
www.xppower.com
17 Sept 19