Models and Ratings - Convection-cooled  
Output Power  
210 W  
Output Voltage V1  
12.0 VDC  
Max Output Current  
17.50 A  
Model Number  
AHM250PS12T  
AHM250PS15T  
AHM250PS19T  
AHM250PS24T  
AHM250PS48T  
220 W  
240 W  
250 W  
250 W  
15.0 VDC  
19.0 VDC  
24.0 VDC  
48.0 VDC  
14.66 A  
12.63 A  
10.41 A  
5.21 A  
Notes:  
1. For optional input connector retention clip, add suffix ‘-A’ to the model number e.g. AHM250PS24T-A.  
2. For 6 pin DIN connector, remove ‘T’ from the end of the model number e.g. AHM250PS24 (DIN connector for medical applications only).  
Input Characteristics  
Characteristic  
Input Voltage - Operating  
Input Frequency  
Minimum  
Typical  
115/230  
50/60  
Maximum  
264  
Units  
VAC  
Hz  
Notes & Conditions  
Derate <100 VAC (see fig. 1)  
80  
47  
63  
>
Power Factor  
0.9  
EN61000-3-2 class A & D compliant & Energy Star Compliant  
Input Current - No Load  
Input Current - Full Load  
Inrush Current  
0.09/0.10  
2.3/1.2  
60-80  
0.3/0.35  
60/120  
0.4/0.8  
A
A
A
W
μA  
mA  
115/230 VAC  
115/230 VAC  
120  
0.5  
200  
230 VAC cold start, 25 şC  
115/230 VAC  
115 V 60 Hz/230 V 50 Hz (Typ.), 264 VAC/60 Hz (Max.)  
115/230 VAC/400 Hz  
No Load Input Power  
Earth Leakage Current  
Input Protection  
T6.3A/250 V internal fuse in both lines  
Output Characteristics  
Characteristic  
Output Voltage - V1  
Output Voltage Adjustment  
Minimum Load  
Start Up Delay  
Hold Up Time  
Minimum  
Typical  
Maximum  
Units  
VDC  
%
Notes & Conditions  
12  
48  
See Models and Ratings table  
No user adjustment  
0
A
300/200  
15  
ms  
ms  
%
115/230 VAC full load (see fig.2)  
115/230 VAC full load (see fig.3)  
After 20 min warm up  
Drift  
0.2  
0.5  
4
Line Regulation  
Load Regulation  
%
90-264 VAC (50% load)  
0f50g100% load.  
%
Recovery within 1% in less than 500 μs for a 50-75% and 75-  
50% load step  
Transient Response - V1  
5
%
Over/Undershoot - V1  
Ripple & Noise  
3
%
% pk-pk  
%
<1  
1.5  
20 MHz bandwidth with external circuit (see fig.4-7)  
Vnom, Recycle AC to reset  
AHM250PS12  
125  
13.2  
16.5  
21.0  
26.4  
52.8  
115.0  
21.0  
17.6  
18  
22  
AHM250PS15  
Overvoltage Protection  
Overload Protection  
28  
VDC  
%
AHM250PS19  
33  
AHM250PS24  
59  
AHM250PS48  
175  
29.8  
26.3  
21.5  
17.7  
8.9  
I nom, Auto reset  
AHM250PS12  
AHM250PS15  
15.2  
11.5  
5.7  
A
AHM250PS19  
AHM250PS24  
AHM250PS48  
Short Circuit Protection  
Temperature Coefficient  
Overtemperature Protection  
Continuous, trip & restart (hiccup mode)  
0.05  
%/˚C  
°C  
Connected to transformer. Auto reset.  
2