xppower.com
Models and Ratings - Convection-cooled
Output Power
100 W
100 W
100 W
90 W
Output Voltage V1
12.0 VDC
15.0 VDC
19.0 VDC
24.0 VDC
24.0 VDC
48.0 VDC
12.0 VDC
15.0 VDC
19.0 VDC
24.0 VDC
24.0 VDC
48.0 VDC
Max Output Current
8.33 A
Peak(2)
Model Number(1)
AHM100PS12
AHM100PS15
AHM100PS19
AHM100PS24P(3)
AHM100PS24
6.67 A
5.26 A
3.75 A
4.16 A
2.08 A
8.33 A
6.67 A
5.26 A
7 A
100 W
100 W
100 W
100 W
100 W
90 W
AHM100PS48
AHM100PS12C2
AHM100PS15C2
AHM100PS19C2
AHM100PS24C2P(3)
AHM100PS24C2
AHM100PS48C2
3.75 A
4.16 A
2.08 A
7 A
100 W
100 W
Notes:
1. Models with suffix ‘C2’ have a Class II equipment protection classification.
2. Maximum peak duration 300 ms, average power must not exceed 90 W.
3. Peak models are not standard product. Contact sales for details and availability.
4. For optional input connector retention clip, add suffix ‘-A’ to the model number
e.g. AHM100PS24C2-A.
Input Characteristics
Characteristic
Minimum
Typical
115/230
50/60
Maximum
264
Units
VAC
Hz
Notes & Conditions
Full power 90 VAC to 264 VAC. Derate output power linearly by
20% from 90 VAC to 80 VAC.
Input Voltage - Operating
80
47
Input Frequency
63
>
Power Factor
0.9
EN61000-3-2 class A & D compliant & Energy Star Compliant
Input Current - No Load
Input Current - Full Load
Inrush Current
0.05/0.09
1.0/0.5
60-80
0.3/0.4
50/85
A
A
A
W
µA
mA
115/230 VAC
115/230 VAC
120
0.5
180
230 VAC cold start, 25 ºC
115/230 VAC
115 V 60 Hz/230 V 50 Hz (Typ.), 264 VAC/60 Hz (Max.)
115/230 VAC/400 Hz
No Load Input Power
Earth Leakage Current
Input Protection
0.3/0.6
T2.5A/250 V internal fuse in both lines
Output Characteristics
Characteristic
Output Voltage - V1
Output Voltage Adjustment
Minimum Load
Start Up Delay
Hold Up Time
Minimum
Typical
Maximum
Units
VDC
%
Notes & Conditions
12
48
See Models and Ratings table
No user adjustment
0
A
200/100
20
ms
ms
%
115/230 VAC full load (see fig.1)
115/230 VAC full load (see fig.2)
After 20 min warm up
Drift
0.2
0.5
3
Line Regulation
Load Regulation
%
90-264 VAC (50% load)
0f50g100% load.
%
Recovery within 1% in less than 500 µs for a 50-75% and 75-
50% load step
Transient Response - V1
5
%
Over/Undershoot - V1
Ripple & Noise
3
%
% pk-pk
%
<1
1.5
20 MHz bandwidth with external circuit (see fig.3-6)
Vnom, Recycle AC to reset
AHM100PS12 & C2
125
13.2
16.5
21.0
26.4
52.8
115.0
10.0
8.0
18
22
AHM100PS15 & C2
Overvoltage Protection
28
VDC
%
AHM100PS19 & C2
33
AHM100PS24 & C2
59
AHM100PS48 & C2
175
14.0
11.4
9.0
7.1
3.6
I nom, Auto reset
AHM100PS12 & C2
AHM100PS15 & C2
Overload Protection
6.3
A
AHM100PS19 & C2
5.0
AHM100PS24 & C2
2.5
AHM100PS48 & C2
Short Circuit Protection
Temperature Coefficient
Overtemperature Protection
Continuous, trip & restart (hiccup mode)
0.05
%/˚C
°C
Connected to transformer. Auto reset.
2