xppower.com  
Models and Ratings - Convection-cooled  
Output Power  
100 W  
100 W  
100 W  
90 W  
Output Voltage V1  
12.0 VDC  
15.0 VDC  
19.0 VDC  
24.0 VDC  
24.0 VDC  
48.0 VDC  
12.0 VDC  
15.0 VDC  
19.0 VDC  
24.0 VDC  
24.0 VDC  
48.0 VDC  
Max Output Current  
8.33 A  
Peak(2)  
Model Number(1)  
AHM100PS12  
AHM100PS15  
AHM100PS19  
AHM100PS24P(3)  
AHM100PS24  
6.67 A  
5.26 A  
3.75 A  
4.16 A  
2.08 A  
8.33 A  
6.67 A  
5.26 A  
7 A  
100 W  
100 W  
100 W  
100 W  
100 W  
90 W  
AHM100PS48  
AHM100PS12C2  
AHM100PS15C2  
AHM100PS19C2  
AHM100PS24C2P(3)  
AHM100PS24C2  
AHM100PS48C2  
3.75 A  
4.16 A  
2.08 A  
7 A  
100 W  
100 W  
Notes:  
1. Models with suffix ‘C2’ have a Class II equipment protection classification.  
2. Maximum peak duration 300 ms, average power must not exceed 90 W.  
3. Peak models are not standard product. Contact sales for details and availability.  
4. For optional input connector retention clip, add suffix ‘-A’ to the model number  
e.g. AHM100PS24C2-A.  
Input Characteristics  
Characteristic  
Minimum  
Typical  
115/230  
50/60  
Maximum  
264  
Units  
VAC  
Hz  
Notes & Conditions  
Full power 90 VAC to 264 VAC. Derate output power linearly by  
20% from 90 VAC to 80 VAC.  
Input Voltage - Operating  
80  
47  
Input Frequency  
63  
>
Power Factor  
0.9  
EN61000-3-2 class A & D compliant & Energy Star Compliant  
Input Current - No Load  
Input Current - Full Load  
Inrush Current  
0.05/0.09  
1.0/0.5  
60-80  
0.3/0.4  
50/85  
A
A
A
W
µA  
mA  
115/230 VAC  
115/230 VAC  
120  
0.5  
180  
230 VAC cold start, 25 ºC  
115/230 VAC  
115 V 60 Hz/230 V 50 Hz (Typ.), 264 VAC/60 Hz (Max.)  
115/230 VAC/400 Hz  
No Load Input Power  
Earth Leakage Current  
Input Protection  
0.3/0.6  
T2.5A/250 V internal fuse in both lines  
Output Characteristics  
Characteristic  
Output Voltage - V1  
Output Voltage Adjustment  
Minimum Load  
Start Up Delay  
Hold Up Time  
Minimum  
Typical  
Maximum  
Units  
VDC  
%
Notes & Conditions  
12  
48  
See Models and Ratings table  
No user adjustment  
0
A
200/100  
20  
ms  
ms  
%
115/230 VAC full load (see fig.1)  
115/230 VAC full load (see fig.2)  
After 20 min warm up  
Drift  
0.2  
0.5  
3
Line Regulation  
Load Regulation  
%
90-264 VAC (50% load)  
0f50g100% load.  
%
Recovery within 1% in less than 500 µs for a 50-75% and 75-  
50% load step  
Transient Response - V1  
5
%
Over/Undershoot - V1  
Ripple & Noise  
3
%
% pk-pk  
%
<1  
1.5  
20 MHz bandwidth with external circuit (see fig.3-6)  
Vnom, Recycle AC to reset  
AHM100PS12 & C2  
125  
13.2  
16.5  
21.0  
26.4  
52.8  
115.0  
10.0  
8.0  
18  
22  
AHM100PS15 & C2  
Overvoltage Protection  
28  
VDC  
%
AHM100PS19 & C2  
33  
AHM100PS24 & C2  
59  
AHM100PS48 & C2  
175  
14.0  
11.4  
9.0  
7.1  
3.6  
I nom, Auto reset  
AHM100PS12 & C2  
AHM100PS15 & C2  
Overload Protection  
6.3  
A
AHM100PS19 & C2  
5.0  
AHM100PS24 & C2  
2.5  
AHM100PS48 & C2  
Short Circuit Protection  
Temperature Coefficient  
Overtemperature Protection  
Continuous, trip & restart (hiccup mode)  
0.05  
%/˚C  
°C  
Connected to transformer. Auto reset.  
2