AC-DC
6-25 Watts
AEP Series
•
•
•
•
•
•
•
Universal Input 90-264 VAC
xppower.com
Interchangeable Mains Plug, 10 Watt Models
Continous Short Circuit Protection
EN550022 Class B
Low Cost
6, 10, 15 and 25 Watt Versions
Non-standard Outputs Available
Specification
Input
Input Voltage
Input Frequency
Input Current
• 90-264 VAC
• 47-63 Hz
•
0.2/0.09 A at 115/230 VAC (6W & 10W)
0.3/0.15 A at 115/230 VAC (15W)
0.5/0.3 A at 115/230 VAC (25W)
• 15/30 A max at 115/230 VAC (6W & 10W)
25/50 A max at 115/230 VAC (15W & 25W)
General
Efficiency
• Typically 70% for 6 W,
75% for 10 and 15 W,
80% for 25 W
• 3000 VAC Input to Output
• 60 kHz ± 10 kHz
• >230 kHrs, MIL-HDBK-217F
Inrush Current
Isolation
Switching Frequency
MTBF
Environmental
Output
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
•
•
•
•
See tables
See tables
No minimum load requirement
6 W 100 ms,
10 W 240 ms,
15 W 270 ms,
25 W 280 ms
10 ms typical at 115 VAC,
60 ms typical at 230 VAC
See tables
See tables
1 % pk-pk max (see note 2)
125% typical
Trip and restart (Hiccup mode)
Continuous (auto recovery)
Operating Temperature
• 0 ˚C to +40 ˚C
Storage Temperature
• -20 ˚C to +85 ˚C
EMC & Safety
Emissions
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Dips & Interruptions
EN55022, level B
EN61000-4-2, level 2 Perf Criteria B
EN61000-4-3, level 2 Perf Criteria A
EN61000-4-4, level 2 Perf Criteria B
EN61000-4-5, level 2 Perf Criteria B
EN61000-4-6, level 2 Perf Criteria B
EN61000-4-11, 5 % U
T
10 ms, Perf
Criteria B, 70 % U
T
500 ms,
Perf Criteria C
• EN60950, UL1950,
CSA C22.2 No.234 cUL
•
•
•
•
•
•
•
Hold Up Time
Line Regulation
Load Regulation
Ripple & Noise
Overvoltage Protection
Overload Protection
Short Circuit Protection
•
•
•
•
•
•
•
Safety Approvals