AC-DC
Models and Ratings
Output Voltage
3.3
5.0
6.0
7.5
9.0
12.0
13.6
15.0
18.0
24.0
Notes
1. Initial set accuracy is at 60% full load.
2. Add a 0.1µF E.L capacitor to output for ripple & noise measurement at 20 MHz BW.
3. Line regulation measured from 100 VAC to 240 VAC, full load.
4. Load regulation measured from 60% to full load and from 60% to 20% load (60% ±40% load).
AEP10
Ripple & Noise
(2)
50 mV pk-pk
50 mV pk-pk
1%
1%
1%
1%
1%
1%
1%
1%
Initial Set
Accuracy
(1)
±3%
±2%
±2%
±2%
±2%
±2%
±2%
±2%
±2%
±2%
Line
Regulation
(3)
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
±1%
Load
Regulation
(4)
±4%
±4%
±3%
±3%
±2%
±2%
±2%
±2%
±2%
±2%
Model
Number
AEP10US033
AEP10US05
AEP10US06
AEP10US075
AEP10US09
AEP10US12
AEP10US136
AEP10US15
AEP10US18
AEP10US24
Output Current
1600
1600
1500
1200
1100
850
750
700
550
400
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
V
V
V
V
V
V
V
V
V
V
Mechanical Details 10 Watt Models
All dimensions are in inches (mm)
2.83
(72.0)
1.81
(46.0)
70.87 ±1.97
(1800.0 ±50.0)
1.38
(35.0)
Weight:
0.3 lb (135 g)
Output Plug:
0.22 x 0.10 x 0.37 (5.5 x 2.5 x 9.5)
NB: The AEP10 has four interchangeable mains adapter plugs.
All four mains adapter plugs are supplied with these units.
0.49 (12.5) ±0.002 (0.05)
0.72 (18.3) ±0.002 (0.05)
1.49
(38.0)
1.14
(28.9)
0.75
(19.0)
0.70
(17.7)
0.63
(16.0) 1.50
(38.0)
0.69
(17.4)
0.67
(17.0)
1.10
(28.0)
0.99
(25.1)
1.24
(31.5)
UK
US
EUROPEAN
AUSTRALIAN