80 Watts
xppower.com
AEL80 Series
•
•
•
•
•
•
CEC 2008 & EISA 2007 Compliant
China Compulsory Certfication (CCC) Qualified
Output Voltages from 12 to 48 VDC
High Efficiency
+70 °C Operating Temperature
Compact Dimensions
Specification
Input
General
Input Voltage
Input Frequency
Input Current
Inrush Current
• 90-264 VAC
Efficiency
Isolation
• 85% minimum
• 47-63 Hz
• 3000 VAC Input to Output
1500 VAC Input to Ground
500 VDC Output to Ground
• 1.1 A max
• 15 A/30 A for 115 VAC/230 VAC, cold start
Switching Frequency
MTBF
• 63 kHz typical
Earth Leakage Current • 0.75 mA at 240 VAC
• 300 kHrs to MIL-STD-217F
Power Factor
• Meets EN61000-3-2
Input Protection
• Fitted with internal fuse
• Typically 0.3 W, max 0.5 W
Environmental
Standby Power
Consumption
Operating Temperature • 0 °C to +70 °C, derate from 100% power
at +40 °C to 50% power at +70 °C
Storage Temperature
Cooling
• -40 °C to +85 °C
Output
• Convection cooled
Output Voltage
Minimum Load
Hold Up Time
• See tables
Operating Humidity
Operating Altitude
Shock
• 5-95% RH, non-condensing
• 3000 m
• No minimum load required
• 16 ms min at full load 110 VAC
• 2.0 s at full load 100 VAC
• 10 g, 10 ms on 3 axes
• 5-100 Hz 2.31 m/s2, 20 mins 3 axes
Start Up Delay
Transient Response
Vibration
• 2% deviation, recovery to within 1% of
nominal in 500 µs for 50% load change
EMC & Safety
Emissions
Line Regulation
Load Regulation
Ripple & Noise
• See tables
• EN55022 FCC Part-15C Level B
conducted & radiated
• See tables
• 1% pk-pk max, 20 MHz BW
Harmonic Current
Voltage Flicker
ESD Immunity
Radiated Immunity
EFT/Burst
• EN61000-3-2 Class A
Overvoltage Protection • 112-132%
Overload Protection • 110-150%
Short Circuit Protection • Trip & restart (Hiccup mode), auto recovery
• EN61000-3-3
• EN61000-4-2 Level 3 Perf criteria A
• EN61000-4-3 3 V/m Perf criteria A
• EN61000-4-4 Level 2 Perf criteria A
• EN61000-4-5 Level 3 Perf criteria A
• EN61000-4-6 Level 2 Perf criteria A
• EN61000-4-8 1 A/m Perf criteria A
Temperature
Coefficient
•
0.04%/°C
Surge
Conducted Immunity
Magnetic Field
Dips & Interruptions
T
• EN61000-4-11, 70% U for 500 ms,
T
T
40% U for 100 ms, <5% U for 5000 ms
Perf criteria A, B, B
Safety Approvals
• EN60950-1:2001, UL/cUL60950-1,
China Compulsory Certification (CCC)
qualified, CE Mark.