AC-DC Power Supplies
AEJ50 Series
EMC: Immunity
Phenomenon
Standard
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
Test Level
Criteria
Notes & Conditions
ESD
8 kV Air, 6 kV contact
3 V/m
A
A
A
A
A
Radiated
EFT/Burst
Surge
Conducted
Magnetic Fields
2
Installation Class 3
3 V
3 A/m
A
Dip: 30% 500 ms
Dip: 60% 100 ms
Int: 100% 5000 ms
Int: 100% 10 ms
A/B
A/B
B
High Line/Low Line
High Line/Low Line
Dips and Interruptions
EN61000-4-11
A
Safety Approvals
Safety Agency
Safety Standard
UL60950-1
Notes & Conditions
UL
TUV
CB
EN60950-1
IEC60950-1
Mechanical Details
Cable length
12-19 V:
48” (1220 mm) 16 AWG
24-48 V:
48” (1220 mm) 18 AWG
2.09
(53.0)
0.47
(12.00)
4.72
(120.0)
IEC320-C14
1.24
(31.5)
Notes
1. All dimensions shown in inches (mm).
2. Weight: 0.60 lbs (300 g) approx.
4. Output connector is 5.5 mm dia. outer barrel, inner dia. is 2.5 mm with a center +
and outer shell - polarity.
3. Tolerance is 0.02 ( 0.5) maximum, except output cable length
which is 2” ( 50 mm)
www.xppower.com
07 June 16