AC-DC Power Supplies
AEJ36 Series
Input
Characteristic
Minimum
Typical
Maximum
264
Units
Notes & Conditions
Input Voltage
90
47
VAC
Input Frequency
Input Current
63
Hz
A
1.0
Measured at 100VAC
Inrush Current
60
A
230 VAC, cold start at 25 °C
No Load Input Power
Input Protection
0.075
W
T2.0A/250 VAC internal fuse in line
Output
Characteristic
Min.
Typ.
Max.
Units
Notes & Conditions
Output Voltage
Initial Set Accuracy
Minimum Load
Start Up Delay
Start Up Rise Time
Hold Up Time
5
48
2
VDC
%
See Models and Ratings table
At 60% load
No minimum load required
3
20
s
ms
ms
%
8
Full load and 115 VAC
Line Regulation
Total Regulation
1
6
%
Maximum deviation, recovering to less than 1% within
500 µs for 25% step load
Transient Response
5
%
Measured with 20 MHz Bandwidth and 10 µF electrolytic in
parallel with 0.1 µF ceramic capacitor.
Ripple and Noise
1
% pk-pk
Overshoot
5
%
%
%
At turn on / turn off
Overload Protection
Overvoltage Protection
Short Circuit Protection
Temperature Coefficient
115
117
175
143
Recycle mains to reset
Trip and restart (hiccup), auto resetting
0.05
%/°C
Environmental
Characteristic
Minimum
Typical
Maximum
Units
Notes & Conditions
Operating Temperature
Cooling
-20
+60
°C
Derate from 100% load at 40 °C to 60% load at 60 °C
Natural convection
Operating Humidity
Storage Temperature
Operating Altitude
Shock
5
-20
90
+85
2000
%RH
°C
m
Non-condensing
IEC68-2-27, 30 g, 11 ms half sine, 3 times in each of 6 axes
Vibration
IEC68-2-6, 10-500 Hz, 2 g 10 mins/sweep, 60 mins for each of 3 axes
Derating Curve
100
80
60
40
20
60
-20
40
Ambient Temperature (ºC)
www.xppower.com
2