Platform Cable USB II  
approximately 40 seconds over a USB 2.0 port and 60 seconds over a USB 1.1 port. Reprogramming times vary depending  
on the Xilinx design tool version, the type of USB port and the performance of the host system.  
During a PROM update, the cable's status LED illuminates red (Figure 8, page 10), and a progress bar indicates  
communication activity. PROM updates should never be interrupted. When an update is complete, the status LED returns to  
either amber or green, and the cable is ready for normal operation.  
Hot Plug and Play  
Platform Cable USB II can be attached and removed from the host computer without the need to power-down or reboot.  
There is a momentary delay after connecting the cable to an available port before the status LED illuminates — this process  
is called enumeration.  
Connecting to the Cable in iMPACT  
This section describes some of the ways to connect to Platform Cable USB II using the Xilinx iMPACT graphical user  
interface (GUI). For cable communication using other Xilinx design tools or methods, please refer to the appropriate software  
user guide.  
Select a Flow  
From the iMPACT GUI, select a flow on the “Modes” tab (Figure 3). Double-click on the desired flow.  
X-Ref Target - Figure 3  
DS593_03_021408  
Figure 3: iMPACT (9.2i) Modes Tab  
Note: For a description of the different flows, please refer to iMPACT Help.  
Establishing a Connection  
Once a flow is selected, there are a number of ways to establish a connection with the cable. Two common options are  
described here:  
Option 1: Cable Auto Connect  
To auto connect the cable, select Output Cable Auto Connect (Figure 4).  
Note: During the auto-connect sequence, iMPACT selects Parallel Cable IV (PC4) as the active cable if both PC4 and Platform Cable  
USB II are connected to the same host system. If two or more USB cables are connected to the same host, the active cable is the first USB  
cable physically connected to the host system. See Multiple USB Cable Management, page 7, for information on controlling more than one  
USB cable from a single application.  