欢迎访问ic37.com |
会员登录 免费注册
发布采购

5962-9473002MXC 参数 Datasheet PDF下载

5962-9473002MXC图片预览
型号: 5962-9473002MXC
PDF下载: 下载PDF文件 查看货源
内容描述: [Field Programmable Gate Array, 576 CLBs, 10000 Gates, 90.9MHz, 1368-Cell, CMOS, CPGA223, CERAMIC, PGA-223]
分类和应用: 时钟可编程逻辑
文件页数/大小: 68 页 / 685 K
品牌: XILINX [ XILINX, INC ]
 浏览型号5962-9473002MXC的Datasheet PDF文件第21页浏览型号5962-9473002MXC的Datasheet PDF文件第22页浏览型号5962-9473002MXC的Datasheet PDF文件第23页浏览型号5962-9473002MXC的Datasheet PDF文件第24页浏览型号5962-9473002MXC的Datasheet PDF文件第26页浏览型号5962-9473002MXC的Datasheet PDF文件第27页浏览型号5962-9473002MXC的Datasheet PDF文件第28页浏览型号5962-9473002MXC的Datasheet PDF文件第29页  
R
XC4000E and XC4000X Series Field Programmable Gate Arrays  
Quad  
Single  
Double  
Long  
Direct  
Connect  
CLB  
Long  
Quad  
Long Global Long Double Single Global Carry Direct  
Clock  
Clock Chain Connect  
x5994  
Figure 25: High-Level Routing Diagram of XC4000 Series CLB (shaded arrows indicate XC4000X only)  
6
Table 14: Routing per CLB in XC4000 Series Devices  
XC4000E  
XC4000X  
Vertical Horizontal Vertical Horizontal  
Singles  
Doubles  
Quads  
8
4
0
6
0
8
4
0
6
0
8
4
8
4
Double  
Singles  
Double  
12  
10  
2
12  
6
Longlines  
Six Pass Transistors  
Per Switch Matrix  
Interconnect Point  
Direct  
Connects  
2
Globals  
Carry Logic  
Total  
4
2
0
0
8
1
0
0
X6600  
Figure 26: Programmable Switch Matrix (PSM)  
24  
18  
45  
32  
Single-Length Lines  
Programmable Switch Matrices  
Single-length lines provide the greatest interconnect flexi-  
bility and offer fast routing between adjacent blocks. There  
are eight vertical and eight horizontal single-length lines  
associated with each CLB. These lines connect the switch-  
ing matrices that are located in every row and a column of  
CLBs.  
The horizontal and vertical single- and double-length lines  
intersect at a box called a programmable switch matrix  
(PSM). Each switch matrix consists of programmable pass  
transistors used to establish connections between the lines  
(see Figure 26).  
For example, a single-length signal entering on the right  
side of the switch matrix can be routed to a single-length  
line on the top, left, or bottom sides, or any combination  
thereof, if multiple branches are required. Similarly, a dou-  
ble-length signal can be routed to a double-length line on  
any or all of the other three edges of the programmable  
switch matrix.  
Single-length lines are connected by way of the program-  
mable switch matrices, as shown in Figure 28. Routing  
connectivity is shown in Figure 27.  
Single-length lines incur a delay whenever they go through  
a switching matrix. Therefore, they are not suitable for rout-  
ing signals for long distances. They are normally used to  
conduct signals within a localized area and to provide the  
branching for nets with fanout greater than one.  
May 14, 1999 (Version 1.6)  
6-29  
 
 复制成功!