R
Spartan-II/Spartan-IIE Family OTP Configuration PROMs (XC17S00A)
AC Characteristics Over Operating Condition
(1)
TCEH
CE
TSCE
TSCE
THCE
ESET/OE
TLC
THC
TCYC
THOE
CLK
TOE
TCE
TCAC
TOH
TDF
DATA
TOH
DS030_03_111502
Symbol
T
OE
T
CE
T
CAC
T
OH
T
DF
T
CYC
T
LC
T
HC
T
SCE
T
HCE
T
HOE
T
CEH
RESET/OE to Data Delay
CE to Data Delay
CLK to Data Delay
Description
Min
-
-
-
0
-
100
50
50
25
0
25
20
Max
45
60
80
-
50
-
-
-
-
-
-
-
Units
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Data Hold From CE, RESET/OE, or CLK
(2)
CE or RESET/OE to Data Float Delay
(2,3)
Clock Periods
CLK Low Time
(2)
CLK High Time
(2)
CE Setup Time to CLK (to guarantee proper counting)
CE Hold Time to CLK (to guarantee proper counting)
RESET/OE Hold Time (guarantees counters are reset)
CE High time (guarantees counters are reset)
Notes:
1. AC test load = 50 pF
2. Guaranteed by design, not tested.
3. Float delays are measured with 5 pF AC loads. Transition is measured at ±200 mV from steady state active levels.
4. All AC parameters are measured with V
IL
= 0.0V and V
IH
= 3.0V.
5. If T
CEH
High < 2µs, T
CE
= 2
µs.
6. If T
HOE
High < 2µs, T
CE
= 2
µs.
DS078 (v1.8) November 18, 2002
Advance Product Specification
1-800-255-7778
7