X9312
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Supply Voltage
Limits
Commercial
Industrial
Military
0°C
+70°C
+85°C
+125°C
X9312
5V ±10%
3865 PGM T04.1
–40°C
–55°C
3865 PGM T03.1
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified.)
Limits
(4)
Symbol
Parameter
Min.
Typ.
Max.
Units
Test Conditions
CS = V , U/D = V or V and
I
I
I
V
Active Current
1
3
mA
CC
SB
LI
CC
IL
IL
IH
INC = 0.4V/2.4V @ max. t
CYC
Standby Supply Current
500
1000
µA
µA
V
CS = V – 0.3V, U/D and INC =
CC
V
SS
or V – 0.3V
CC
CS, INC, U/D Input
Leakage Current
±10
V
IN
= V to V
SS CC
V
V
CS, INC, U/D Input
HIGH Voltage
2
V
+ 1
CC
IH
CS, INC, U/D Input
–1
0.8
V
IL
LOW Voltage
R
Wiper Resistence
40
100
15
Ω
V
Max. Wiper Current ±1mA
W
V
VH
V
VL
VH Terminal Voltage
VL Terminal Voltage
0
0
15
V
(5)
C
IN
CS, INC, U/D Input
10
pF
V
CC
= 5V, V = V
,
IN
SS
Capacitance
T = 25°C, f = 1MHz
A
3865 PGM T05.3
STANDARD PARTS
Part Number
Maximum Resistance
Wiper Increments
Minimum Resistance
X9312Z
X9312W
X9312U
X9312T
1KΩ
10KΩ
50KΩ
100KΩ
10.1Ω
101Ω
505Ω
1010Ω
40Ω
40Ω
40Ω
40Ω
3865 PGM T08.1
Notes: (4) Typical values are for T = 25°C and nominal supply voltage.
A
(5) This parameter is periodically sampled and not 100% tested.
5