X9221
D.C. OPERATING CHARACTERISTICS
(Over recommended operating conditions unless otherwise stated.)
Limits
Symbol
l
CC
I
SB
I
LI
I
LO
V
IH
V
IL
V
OL
Parameter
Supply Current (Active)
V
CC
Current (Standby)
Input Leakage Current
Output Leakage Current
Input HIGH Voltage
Input LOW Voltage
Output LOW Voltage
Min. Typ.
200
Max.
3
500
10
10
Unit
mA
µA
µA
µA
V
V
V
I
OL
= 3mA
Test Conditions
f
SCL
= 100kHz, SDA = Open, Other Inputs = V
SS
SCL = SDA = V
CC
, Addr. = V
SS
V
IN
= V
SS
to V
CC
V
OUT
= V
SS
to V
CC
–1
0.8
0.4
ENDURANCE AND DATA RETENTION
Parameter
Minimum endurance
Data retention
Min.
100
fo
r
N
Notes:
(1) Absolute Linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when used
as a potentiometer.
(2) Relative Linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a poten-
tiometer. It is a measure of the error in step size.
(3) MI = RTOT/63 or (V
H
/R
H
–V
L
/R
L
)/63, single pot
ew
8
6
100,000
Data changes per bit per register
years
CAPACITANCE
Symbol
C
I/O
(5)
C
IN
(5)
Parameter
en
d
ed
Max.
Input/output capacitance (SDA)
D
es
Unit
Unit
pF
pF
2
V
CC
+ 1
Symbol
t
PUR
(6)
t
PUW
(6)
t
R
V
CC
ec
om
POWER-UP TIMING
m
Input capacitance (A0, A1, A2, A3 and SCL)
Parameter
Max.
1
5
50
Power-up to initiation of read operation
Power-up to initiation of write operation
V
CC
Power-up range rate
A.C. CONDITIONS OF TEST
N
Input pulse levels
ot
R
V
CC
x 0.1 to V
CC
x 0.9
10ns
V
CC
x 0.5
Input rise and fall times
Input and output timing levels
Notes:
(5) This parameter is periodically sampled and not 100%
tested.
(6) t
PUR
and t
PUW
are the delays required from the time
V
CC
is stable until the specified operation can be initi-
ated. These parameters are periodically sampled and not
100% tested.
REV 1.1 8/8/02
ig
ns
Test Conditions
V
I/O
= 0V
V
IN
= 0V
Unit
ms
ms
V/nsec
www.xicor.com
Characteristics subject to change without notice.
9 of 15