ABSOLUTE MAXIMUM RATINGS*
Temperature Under Bias
X24164 ...................................... –65°C to +135°C
Storage Temperature ....................... –65°C to +150°C
Voltage on any Pin with
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation of
the device at these or any other conditions above those
indicatedintheoperationalsectionsofthisspecificationis
not implied. Exposure to absolute maximum rating condi-
tions for extended periods may affect device reliability.
Respect to V
................................ –1.0V to +7.0V
SS
D.C. Output Current ............................................ 5 mA
Lead Temperature (Soldering, 10 Seconds) ..... 300°C
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Supply Voltage
Limits
Commercial
Industrial
Military
0°C
70°C
+85°C
+125°C
X24164
4.5V to 5.5V
3V to 5.5V
–40°C
–55°C
X24164-3
X24164-2.7
2.7V to 5.5V
3846 PGM T02
3846 PGM T03
D.C. OPERATING CHARACTERISTICS (Over recommended operating conditions unless otherwise specified.)
Limits
Symbol
Parameter
Min.
Max.
Units
Test Conditions
ICC1
VCC Supply Current (Read)
1
mA SCL = VCC X 0.1/VCC X 0.9 Levels
@ 100 KHz, SDA = Open, All
Other
ICC2
VCC Supply Current (Write)
VCC Standby Current
3
mA Inputs = GND or VCC – 0.3V
(1)
ISB1
150
µA
SCL = SDA = VCC, All Other
Inputs = GND or VCC – 0.3V,
VCC = 5V ± 10%
(1)
ISB2
VCC Standby Current
50
µA
SCL = SDA = VCC, All Other
Inputs = GND or VCC – 0.3V,
VCC = 3V
ILI
Input Leakage Current
Output Leakage Current
Input Low Voltage
10
10
µA
µA
V
VIN = GND to VCC
ILO
VOUT = GND to VCC
(2)
VlL
–1.0
VCC x 0.3
(2)
VIH
Input High Voltage
VCC x 0.7 VCC + 0.5
0.4
V
VOL
Output Low Voltage
V
IOL = 3 mA
3846 PGM T04
CAPACITANCE TA = 25°C, f = 1.0 MHz, VCC = 5V
Symbol
Parameter
Max.
Units
Test Conditions
(3)
CI/O
Input/Output Capacitance (SDA)
8
6
pF
pF
VI/O = 0V
VIN = 0V
(3)
CIN
Input Capacitance (S0, S1, S2, SCL)
3846 PGM T05
Notes: (1) Must perform a stop command prior to measurement.
(2) V min. and V max. are for reference only and are not 100% tested.
IL IH
(3) This parameter is periodically sampled and not 100% tested.
9