欢迎访问ic37.com |
会员登录 免费注册
发布采购

X24128P 参数 Datasheet PDF下载

X24128P图片预览
型号: X24128P
PDF下载: 下载PDF文件 查看货源
内容描述: 400kHz的2线串行E2PROM与锁座 [400KHz 2-Wire Serial E2PROM with Block Lock]
分类和应用: 存储内存集成电路光电二极管双倍数据速率可编程只读存储器电动程控只读存储器电可擦编程只读存储器时钟
文件页数/大小: 17 页 / 89 K
品牌: XICOR [ XICOR INC. ]
 浏览型号X24128P的Datasheet PDF文件第4页浏览型号X24128P的Datasheet PDF文件第5页浏览型号X24128P的Datasheet PDF文件第6页浏览型号X24128P的Datasheet PDF文件第7页浏览型号X24128P的Datasheet PDF文件第9页浏览型号X24128P的Datasheet PDF文件第10页浏览型号X24128P的Datasheet PDF文件第11页浏览型号X24128P的Datasheet PDF文件第12页  
X24128
Random Read
Random read operation allows the master to access
any memory location in the array. Prior to issuing
the Slave Address Byte with the R/W bit set to one,
the master must first perform a “Dummy” write oper-
ation. The master issues the start condition and the
Slave Address Byte with the R/W bit low, receives
an acknowledge, then issues the Word Address
Byte 1, receives another acknowledge, then issues
the Word Address Byte 0. After the device acknowl-
edges receipt of the Word Address Byte 0, the
master issues another start condition and the Slave
Address Byte with the R/W bit set to one. This is
followed by an acknowledge and then eight bits of
data from the device. The master terminates the
read operation by not responding with an acknowl-
edge and then issuing a stop condition. Refer to
figure 9 for the address, acknowledge, and data
transfer sequence.
The device will perform a similar operation called “Set
Current Address” if a stop is issued instead of the
second start shown in figure 9. The device will go into
standby mode after the stop and all bus activity will be
ignored until a start is detected. The effect of this oper-
ation is that the new address is loaded into the
address counter, but no data is output by the device.
The next Current Address Read operation will read
from the newly loaded address.
Sequential Read
Sequential reads can be initiated as either a current
address read or random read. The first Data Byte is
transmitted as with the other modes; however, the
master now responds with an acknowledge, indicating
it requires additional data. The device continues to
output data for each acknowledge received. The
master terminates the read operation by not
responding with an acknowledge and then issuing a
stop condition.
The data output is sequential, with the data from address
n followed by the data from address n + 1. The address
counter for read operations increments through all byte
addresses, allowing the entire memory contents to be
read during one operation. At the end of the address
space the counter “rolls over” to address 0000h and the
device continues to output data for each acknowledge
received. Refer to figure 10 for the acknowledge and
data transfer sequence.
Figure 9. Random Read Sequence
SIGNALS
FROM THE
MASTER
SDA BUS
SIGNALS
FROM THE
SLAVE
S
T
A
R
T
S
T
A
R
T
S
A
C
K
A
C
K
A
C
K
SLAVE
ADDRESS
WORD ADDRESS WORD ADDRESS
BYTE 1
BYTE 0
SLAVE
ADDRESS
1
A
C
K
S
T
O
P
P
S1 0 1 0
0
DATA
7027 FM 11
Figure 10. Sequential Read Sequence
SIGNALS
FROM THE
MASTER
SDA BUS
SIGNALS
FROM THE
SLAVE
A
C
K
1
A
C
K
A
C
K
A
C
K
S
T
O
P
P
SLAVE
ADDRESS
S
DATA
(1)
DATA
(2)
DATA
(n–1)
DATA
(n)
(n is any integer greater than 1)
7027 FM 12
8