X1228  
A final application for the ATR control is in-circuit cali-  
bration for high accuracy applications, along with a  
temperature sensor chip. Once the RTC circuit is pow-  
ered up with battery backup, the PHZ output is set at  
32.768kHz and frequency drift is measured. The ATR  
control is then adjusted to a setting which minimizes  
drift. Once adjusted at a particular temperature, it is  
possible to adjust at other discrete temperatures for  
minimal overall drift, and store the resulting settings in  
the EEPROM. Extremely low overall temperature drift  
is possible with this method. The Xicor evaluation  
board contains the circuitry necessary to implement  
this control.  
The X1 and X2 connections to the crystal are to be  
kept as short as possible. A thick ground trace around  
the crystal is advised to minimize noise intrusion, but  
ground near the X1 and X2 pins should be avoided as  
it will add to the load capacitance at those pins. Keep in  
mind these guidelines for other PCB layers in the vicin-  
ity of the RTC device. A small decoupling capacitor at  
the Vcc pin of the chip is mandatory, with a solid con-  
nection to ground.  
Assembly  
Most electronic circuits do not have to deal with  
assembly issues, but with the RTC devices assembly  
includes insertion or soldering of a live battery into an  
unpowered circuit. If a socket is soldered to the board,  
and a battery is inserted in final assembly, then there  
are no issues with operation of the RTC. If the battery  
is soldered to the board directly, then the RTC device  
Vback pin will see some transient upset from either sol-  
dering tools or intermittent battery connections which  
can stop the circuit from oscillating. Once the battery is  
soldered to the board, the only way to assure the circuit  
will start up is to momentarily (very short period of  
time!) short the Vback pin to ground and the circuit will  
begin to oscillate.  
For more detailed operation see Xicor’s application  
note AN154 on Xicor’s website at www.xicor.com.  
Layout Considerations  
The crystal input at X1 has a very high impedance and  
will pick up high frequency signals from other circuits  
on the board. Since the X2 pin is tied to the other side  
of the crystal, it is also a sensitive node. These signals  
can couple into the oscillator circuit and produce dou-  
ble clocking or mis-clocking, seriously affecting the  
accuracy of the RTC. Care needs to be taken in layout  
of the RTC circuit to avoid noise pickup. Below in Fig-  
ure 15 is a suggested layout for the X1228 device.  
Oscillator Measurements  
When a proper crystal is selected and the layout guide-  
lines above are observed, the oscillator should start up  
in most circuits in less than one second. Some circuits  
may take slightly longer, but startup should definitely  
occur in less than 5 seconds. When testing RTC cir-  
cuits, the most common impulse is to apply a scope  
probe to the circuit at the X2 pin (oscillator output) and  
observe the waveform. DO NOT DO THIS! Although in  
some cases you may see a useable waveform, due to  
the parasitics (usually 10pF to ground) applied with the  
scope probe, there will be no useful information in that  
waveform other than the fact that the circuit is oscillat-  
ing. The X2 output is sensitive to capacitive impedance  
so the voltage levels and the frequency will be affected  
by the parasitic elements in the scope probe. Applying  
a scope probe can possibly cause a faulty oscillator to  
start up, hiding other issues (although in the Xicor  
RTC’s, the internal circuitry assures startup when  
using the proper crystal and layout).  
Figure 15. Suggested Layout for Xicor RTC in SO-14  
C1  
0.1µF  
R1 10k  
U1  
XTAL1  
X1228  
32.768kGz  
Characteristics subject to change without notice. 25 of 31  
REV 1.3 3/24/04  
www.xicor.com  