X1226  
chip will be running from the battery. If Vback falls to  
lower than Vtrip, then the chip shuts down and all out-  
puts are disabled except for the oscillator and time-  
keeping circuitry. The fact that the chip can be powered  
from Vback is not necessarily an issue since standby  
current for the RTC devices is <2µA for this mode  
(called main timekeeping currentin the data sheet).  
Only when the serial interface is active is there an  
increase in supply current, and with Vcc powered  
down, the serial interface will most likely be inactive.  
PERFORMANCE DATA  
Performance  
I
BACK  
I
vs. Temperature  
BACK  
Multi-Lot Process Variation Data  
1.4  
3.3V  
1.2  
1.0  
0.8  
0.6  
0.4  
0.2  
0
1.8V  
One way to prevent operation in battery backup mode  
above the Vtrip level is to add a diode drop (silicon  
diode preferred) to the battery to insure it is below  
Vtrip. This will also provide reverse leakage protection  
which may be needed to get safety agency approval.  
-40  
25  
60  
85  
One mode that should always be avoided is the opera-  
tion of the RTC device with Vback greater than both  
Vcc and Vtrip (Condition 2d in Table 8). This will cause  
the battery to drain quickly as serial bus communica-  
tion and non-volatile writes will require higher supplier  
current.  
Temperature °C  
Characteristics subject to change without notice. 21 of 24  
REV 1.1.24 1/13/03  
www.xicor.com  