ISL29038
2
I C Electrical Specifications
For SCL and SDA unless otherwise noted, V = 3V, T = +25°C, R = 499kΩ 1% tolerance (Note 10). (Continued)
EXT
DD
A
SYMBOL
PARAMETER
TEST CONDITIONS
MIN
20 + 0.1xC
20 + 0.1xC
600
TYP
MAX UNITS
t
Rise Time of both SDA and SCL Signals
Fall Time of both SDA and SCL Signals
Set-up Time for STOP Condition
(Note 11)
(Note 11)
ns
ns
ns
ns
R
b
b
t
F
t
SU:STO
t
Bus Free Time Between a STOP and START Condition
Capacitive Load for Each Bus Line
SDA and SCL System Bus Pull-Up Resistor
Data Valid Time
1300
BUF
C
400
pF
kΩ
µs
µs
V
b
R
Maximum determined by t and t
F
1
pull-up
VD;DAT
VD:ACK
R
t
0.9
0.9
t
Data Valid Acknowledge Time
V
Noise Margin at the LOW Level
Noise Margin at the HIGH Level
0.1VDD
0.2VDD
nL
V
V
nH
NOTES:
7. Cover glass assumes fixed infrared/visible light transmissivity ratio of 10.
8. The LED light source irradiance is calibrated to produce the same ALS count as a fluorescent light source of the same Lux level.
9. An 850nm infrared LED is used in production test for proximity/IR sensitivity testing.
2
10. All parameters in I C Electrical Specifications table are guaranteed by design and simulation.
11. C is the capacitance of the bus in pF.
b
2
FIGURE 4. I C TIMING DIAGRAM
FN7851.0
October 12, 2012
5