欢迎访问ic37.com |
会员登录 免费注册
发布采购

5962-8852504ZX 参数 Datasheet PDF下载

5962-8852504ZX图片预览
型号: 5962-8852504ZX
PDF下载: 下载PDF文件 查看货源
内容描述: [EEPROM, 32KX8, 200ns, Parallel, CMOS, CDFP28, CERAMIC, FP-28]
分类和应用: 可编程只读存储器电动程控只读存储器电可擦编程只读存储器ATM异步传输模式内存集成电路
文件页数/大小: 28 页 / 238 K
品牌: XICOR [ XICOR INC. ]
 浏览型号5962-8852504ZX的Datasheet PDF文件第1页浏览型号5962-8852504ZX的Datasheet PDF文件第2页浏览型号5962-8852504ZX的Datasheet PDF文件第3页浏览型号5962-8852504ZX的Datasheet PDF文件第5页浏览型号5962-8852504ZX的Datasheet PDF文件第6页浏览型号5962-8852504ZX的Datasheet PDF文件第7页浏览型号5962-8852504ZX的Datasheet PDF文件第8页浏览型号5962-8852504ZX的Datasheet PDF文件第9页  
3.2 Design, construction, and physical dimensions. The design, construction, and physical dimensions shall be as specified
in MIL-PRF-38535, appendix A and herein.
3.2.1 Case outline(s). The case outline(s) shall be in accordance with 1.2.2 herein and on figure 1.
3.2.2 Terminal connections. The terminal connections shall be as specified on figure 2.
3.2.3 Truth table(s). See 3.2.3.1 and 3.2.3.2
3.2.3.1 Unprogrammed or erased devices. The truth table for unprogrammed devices shall be as specified on figure 3.
3.2.3.2 Programmed devices. The requirements for supplying programmed devices are not part of this drawing.
3.3 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance characteristics are
as specified in table I and shall apply over the full case operating temperature range.
3.4 Electrical test requirements. The electrical test requirements shall be the subgroups specified in table II. The electrical
tests for each subgroup are described in table I.
3.5 Marking. Marking shall be in accordance with MIL-PRF-38535, appendix A. The part shall be marked with the PIN listed
in 1.2 herein. In addition, the manufacturer's PIN may also be marked. For packages where marking of the entire SMD PIN
number is not feasible due to space limitations, the manufacturer has the option of not marking the "5962-" on the device.
3.5.1 Certification/compliance mark. A compliance indicator “C” shall be marked on all non-JAN devices built in compliance
to MIL-PRF-38535, appendix A. The compliance indicator “C” shall be replaced with a "Q" or "QML" certification mark in
accordance with MIL-PRF-38535 to identify when the QML flow option is used.
3.6 Certificate of compliance. A certificate of compliance shall be required from a manufacturer in order to be listed as an
approved source of supply in MIL-HDBK-103 (see 6.6 herein). The certificate of compliance submitted to DSCC-VA prior to
listing as an approved source of supply shall affirm that the manufacturer's product meets the requirements of MIL-PRF-38535,
appendix A and the requirements herein.
3.7 Certificate of conformance. A certificate of conformance as required in MIL-PRF-38535, appendix A shall be provided
with each lot of microcircuits delivered to this drawing.
3.8 Notification of change. Notification of change to DSCC-VA shall be required for any change that affects this drawing.
3.9 Verification and review. DSCC, DSCC's agent, and the acquiring activity retain the option to review the manufacturer's
facility and applicable required documentation. Offshore documentation shall be made available onshore at the option of the
reviewer.
3.10 Processing EEPROMS. All testing requirements and quality assurance provisions herein shall be satisfied by the
manufacturer prior to delivery.
3.10.1 Erasure of EEPROMS. When specified, devices shall be erased in accordance with the procedures and
characteristics specified in 4.4.3.
3.10.2 Programmability of EEPROMS. When specified, devices shall be programmed to the specified pattern using the
procedures and characteristics specified in 4.4.2. Software data protect procedures shall be as specified in 4.4.5.
3.10.3 Verification of erasure or programmability of EPROMS. When specified, devices shall be verified as either programmed
to the specified pattern or erased. As a minimum, verification shall consist of reading the device per the procedures and
characteristics specified in 4.4.4. Any bit that does not verify to be in the proper state shall constitute a device failure, and shall
be removed from the lot.
STANDARD
MICROCIRCUIT DRAWING
DEFENSE SUPPLY CENTER COLUMBUS
COLUMBUS, OHIO 43218-3990
DSCC FORM 2234
APR 97
SIZE
A
REVISION LEVEL
5962-88525
SHEET
D
4