From the graph a power loss of 640mW is read. Entering the values in formula (21) results in:
125°C-85°C
θCA(MAX)
<
-1.9°C/W=60.6°C/W
0.64W
θJA(MAX)=θJC + θCA(MAX)=1.9°C/W+60.6°C/W= 62.5°C/W
In order to achieve a θꢅꢆ < 62.5°C/W it would be sufficient to use the minimum area for placing the external components, in
accordance with the indications in the “LAYOUT RECOMMENDATION” section on page 39.