欢迎访问ic37.com |
会员登录 免费注册
发布采购

WM8326GEFL/V 参数 Datasheet PDF下载

WM8326GEFL/V图片预览
型号: WM8326GEFL/V
PDF下载: 下载PDF文件 查看货源
内容描述: 处理器电源管理子系统 [Processor Power Management Subsystem]
分类和应用:
文件页数/大小: 255 页 / 1340 K
品牌: WOLFSON [ WOLFSON MICROELECTRONICS PLC ]
 浏览型号WM8326GEFL/V的Datasheet PDF文件第150页浏览型号WM8326GEFL/V的Datasheet PDF文件第151页浏览型号WM8326GEFL/V的Datasheet PDF文件第152页浏览型号WM8326GEFL/V的Datasheet PDF文件第153页浏览型号WM8326GEFL/V的Datasheet PDF文件第155页浏览型号WM8326GEFL/V的Datasheet PDF文件第156页浏览型号WM8326GEFL/V的Datasheet PDF文件第157页浏览型号WM8326GEFL/V的Datasheet PDF文件第158页  
WM8326  
Production Data  
REFER TO  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
Reset by state machine.  
ON_SYSLO  
Most recent WAKE event type  
0 = Not caused by PVDD  
10  
0
1 = Caused by SYSLO threshold. Note that the SYSLO  
threshold cannot trigger an ON event.  
Reset by state machine.  
ON_WDOG_T  
O
Most recent WAKE event type  
0 = Not caused by Watchdog timer  
1 = Caused by Watchdog timer  
Reset by state machine.  
7
6
0
0
ON_SW_REQ  
Most recent WAKE event type  
0 = Not caused by software WAKE  
1 = Caused by software WAKE command (CHIP_SLP =  
0)  
Reset by state machine.  
ON_RTC_ALM  
ON_ON_PIN  
Most recent ON/WAKE event type  
0 = Not caused by RTC Alarm  
1 = Caused by RTC Alarm  
Reset by state machine.  
5
4
3
0
0
0
Most recent ON/WAKE event type  
0 = Not caused by the ON pin  
1 = Caused by the ON pin  
Reset by state machine.  
RESET_CNV_  
UV  
Most recent ON event type  
0 = Not caused by undervoltage  
1 = Caused by a Device Reset due to a Converter (LDO  
or DC-DC) undervoltage condition  
Reset by state machine.  
RESET_SW  
RESET_HW  
Most recent ON event type  
0 = Not caused by Software Reset  
1 = Caused by Software Reset  
Reset by state machine.  
2
1
0
0
0
0
Most recent ON event type  
0 = Not caused by Hardware Reset  
1 = Caused by Hardware Reset  
Reset by state machine.  
RESET_WDO  
G
Most recent ON event type  
0 = Not caused by the Watchdog  
1 = Caused by a Device Reset triggered by the  
Watchdog timer  
Reset by state machine.  
Register 400Eh ON Source  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
REFER TO  
R16399  
(400Fh)  
OFF Source  
OFF_INTLDO_  
ERR  
Most recent OFF event type  
13  
0
0 = Not caused by LDO13 Error condition  
1 = Caused by LDO13 Error condition  
Reset by state machine.  
OFF_PWR_SE  
Q
Most recent OFF event type  
12  
0
0 = Not caused by Power Sequence Failure  
1 = Caused by a Power Sequence Failure  
PD, June 2012, Rev 4.0  