 浏览型号WM8326GEFL/RV的Datasheet PDF文件第186页浏览型号WM8326GEFL/RV的Datasheet PDF文件第187页浏览型号WM8326GEFL/RV的Datasheet PDF文件第188页浏览型号WM8326GEFL/RV的Datasheet PDF文件第189页浏览型号WM8326GEFL/RV的Datasheet PDF文件第191页浏览型号WM8326GEFL/RV的Datasheet PDF文件第192页浏览型号WM8326GEFL/RV的Datasheet PDF文件第193页浏览型号WM8326GEFL/RV的Datasheet PDF文件第194页  
WM8326  
Production Data  
REFER TO  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
DC-DC1 Voltage Ramp rate  
R16470  
(4056h) DC1  
Control 1  
DC1_RATE  
[1:0]  
15:14  
10  
00 = 1 step every 32us  
01 = 1 step every 16us  
10 = 1 step every 8us  
11 = Immediate voltage change  
DC-DC1 Clock Phase Control  
0 = Normal  
DC1_PHASE  
12  
0
1 = Inverted  
DC1_FREQ  
[1:0]  
DC-DC1 Switching Frequency  
00 = Reserved  
9:8  
00  
01 = 2.0MHz (2.2uH output inductor)  
10 = 4.0MHz (1uH output inductor)  
11 = Reserved  
This field can only be written to by loading configuration  
settings from OTP/ICE. In all other cases, this field is  
Read Only.  
DC1_FLT  
DC-DC1 Output float  
7
0
0 = DC-DC1 output discharged when disabled  
1 = DC-DC1 output floating when disabled  
DC-DC1 Soft-Start Control  
(Duration in each of the 8 startup current limiting steps.)  
00 = 32us steps  
DC1_SOFT_ST  
ART [1:0]  
5:4  
00  
01 = 64us steps  
10 = 128us steps  
11 = 256us steps  
DC1_CAP [1:0]  
DC-DC1 Output Capacitor  
00 = Reserved  
1:0  
00  
01 = Reserved  
10 = 22uF to 47uF  
11 = Reserved  
This field can only be written to by loading configuration  
settings from OTP/ICE. In all other cases, this field is  
Read Only.  
Register 4056h DC1 Control 1  
REGISTER  
ADDRESS  
BIT  
LABEL  
DEFAULT  
DESCRIPTION  
REFER TO  
R16471  
(4057h) DC1  
Control 2  
DC1_ERR_AC  
T [1:0]  
DC-DC1 Error Action (Undervoltage)  
00 = Ignore  
15:14  
00  
01 = Shut down converter  
10 = Shut down system (Device Reset)  
11 = Reserved  
Note that an Interrupt is always raised.  
DC-DC1 Hardware Control Source  
00 = Disabled  
DC1_HWC_SR  
C [1:0]  
12:11  
00  
01 = Hardware Control 1  
10 = Hardware Control 2  
11 = Hardware Control 1 or 2  
DC-DC1 Hardware Control Voltage select  
0 = Set by DC1_ON_VSEL  
1 = Set by DC1_SLP_VSEL  
DC1_HWC_VS  
EL  
10  
0
PD, June 2012, Rev 4.0  