WM7120A  
Pre-Production  
ABSOLUTE MAXIMUM RATINGS  
Absolute Maximum Ratings are stress ratings only. Permanent damage to the device may be caused by continuously operating at  
or beyond these limits. Device functional operating limits and guaranteed performance specifications are given under Electrical  
Characteristics at the test conditions specified.  
ESD Sensitive Device. This device is manufactured on a CMOS process. It is therefore generically susceptible  
to damage from excessive static voltages. Proper ESD precautions must be taken during handling and storage  
of this device.  
Wolfson tests its package types according to IPC/JEDEC J-STD-020 for Moisture Sensitivity to determine acceptable storage  
conditions prior to surface mount assembly. These levels are:  
MSL1 = unlimited floor life at <30C / 85% Relative Humidity. Not normally stored in moisture barrier bag.  
MSL2 = out of bag storage for 1 year at <30C / 60% Relative Humidity. Supplied in moisture barrier bag.  
MSL2A = out of bag storage for 4 weeks at <30°C / 60% Relative Humidity. Supplied in moisture barrier bag.  
MSL3 = out of bag storage for 168 hours at <30C / 60% Relative Humidity. Supplied in moisture barrier bag.  
The Moisture Sensitivity Level for each package type is specified in Ordering Information.  
CONDITION  
MIN  
-0.3V  
-40ºC  
MAX  
+4.2V  
Supply Voltage  
Operating temperature range, TA  
Storage temperature prior to soldering  
Storage temperature after soldering  
+100ºC  
30C max / 60% RH max  
-40ºC  
+100ºC  
IMPORTANT ASSEMBLY GUIDELINES  
Do not put a vacuum over the port hole of the microphone. Placing a vacuum over the port hole can damage the device. For  
information on recommended pick and place vacuum point, refer to the package dimension drawing.  
Do not board wash the microphone after a re-flow process. Board washing and the associated cleaning agents can damage  
the device. Do not expose to ultrasonic cleaning methods.  
Do not use a vapour phase re-flow process. The vapour can damage the device.  
Please refer to application note WAN_0273 for further assembly and handling guidelines.  
RECOMMENDED OPERATING CONDITIONS  
PARAMETER  
Analogue Supply Range  
Ground  
SYMBOL  
VDD  
MIN  
TYP  
MAX  
UNIT  
1.5  
3.7  
V
V
GND  
0
PP, Rev 3.1, April 2012  
4