RoHS
BAV100-103
Electrical Characteristics
T
j
=25℃
Parameter
Forward voltage
Test Conditions
I
F
=100mA
V
R
=50V
V
R
=50 T
j
=100℃
Reverse current
V
R
=100V
V
R
=100V, T
j
=100℃
V
R
=150V
V
R
=150V, T
j
=100℃
V
R
=200V
V
R
=200V, T
j
=100℃
Dynamic forward resistance
Diode capacitance
Reverse recovery time
I
F
=10mA
V
R
=0, f=1MHz
I
F
= I
R
=30mA, I
rr
=3mA,
R
L
=100Ω
BAV100
BAV100
BAV101
BAV101
BAV102
BAV102
BAV103
BAV103
Type
Symbol
V
F
I
R
I
R
I
R
I
R
I
R
I
R
I
R
I
R
r
f
Min
Typ
Max
1.00
100
15
15
15
15
100
100
100
V
Unit
nA
nA
nA
nA
Characteristics
(T
j
=25℃ unless otherwise specified)
W
J
E
E
C
E
L
R
T
O
N
C
I
C
D
t
rr
C
O
5
1.5
L
,
.
50
ns
μA
μA
μA
μA
pF
D
T
Figure 1. Maximum permissible continuous forward
current vs. ambient temperature
Figure 2. Forward current vs. forward voltage
WEJ ELECTRONIC CO.
Http:// www.wej.cn
E-mail:wej@yongerjia.com