W83697HF/F
(4) Read ID
PHASE
R/W
D7
D6
D5
D4
D3
D2
D1
D0
REMARKS
Command
W
W
0
0
MFM
0
0
0
0
0
1
0
0
1
0
Command codes
HDS DS1 DS0
Execution
Result
The first correct ID
information on the cylinder
is stored in Data Register
R
R
R
-------------------- ST0 -----------------------
-------------------- ST1 -----------------------
-------------------- ST2 -----------------------
---------------------- C ------------------------
---------------------- H ------------------------
---------------------- R ------------------------
---------------------- N ------------------------
Status information after
command execution
R
R
Disk status after the
command has been
completed
R
R
Publication Release Date: Feb. 2002
Revision 0.70
- 26 -