W83627HF/ F/ HG/ G
Reserved Register - Index 52h (Bank 4)
This register is reserved for Winbond internal use.
BEEP Control Register 3 - Index 53h (Bank 4)
Register Location:
Power on Default Value:
Attribute:
53h
00h
Read/Write
8 bits
Size:
7
6
5
4
3
2
1
0
EN_5VSB_BP
EN_VBAT_BP
Reserved
Reserved
Reserved
EN_USER_BP
Reserved
Reserved
Bit 7-6: Reserved.
Bit 5: User define BEEP output function. Write 1, the BEEP is always active. Write 0, this function is
inactive. (Default 0)
Bit 4-2: Reserved.
Bit 1: Enable BEEP output from VBAT. Write 1, enable BEEP output, which is default value.
Bit 0: Enable BEEP Output from 5VSB. Write 1, enable BEEP output, which is default value.
Temperature Sensor 1 Offset Register - Index 54h (Bank 4)
Register Location:
Power on Default Value:
Attribute:
54h
00h
Read/Write
8 bits
Size:
7
6
5
4
3
2
1
0
OFFSET1<7:0>
Bit 7-0: Temperature 1 base temperature. The temperature is added by both monitor value and off-
set value.