W83627HF/ F/ HG/ G
VTIN2 Configuration Register - Index 52h (Bank 1)
Register Location:
Power on Default Value
Size:
52h
00h
8 bits
7
6
5
4
3
2
1
0
STOP2
INTMOD
Reserved
FAULT
FAULT
Reserved
Reserved
Reserved
Bit 7-5: Read - Reserved. This bit should be set to 0.
Bit 4-3: Read/Write - Number of faults to detect before setting OVT# output to avoid false tripping
due to noise.
Bit 2: Read - Reserved. This bit should be set to 0.
Bit 1: Read/Write - OVT# Interrupt mode select. This bit default is set to 0, which is compared mode.
When set to 1, interrupt mode will be selected.
Bit 0: Read/Write - When set to 1 the sensor will stop monitor.
VTIN2 Hysteresis(High Byte)Register - Index 53h (Bank 1)
Register Location:
Power on Default Value
Attribute:
53h
4Bh
Read/Write
8 bits
Size:
7
6
5
4
3
2
1
0
THYST2<8:1>
Bit 7-0: Temperature hysteresis bit 8-1, which is High Byte. The temperature default 75 degree C.
Publication Release Date: June 09, 2006
- 63 -
Revision 2.27