Feed-through terminals  
Terminals/Accessories  
SAKG 28 I  
SAKG 28 II  
Y
Y
u
u DNV  
Dimensions/approvals  
Width/length/height (mm)  
Width/length/height (mm)  
a r #  
a r #  
The Weidmüller SAKG range offers the fol-  
lowing connection variants:  
with TS 32 Y  
with TS 35 W  
28/70/63.5  
28/70/53  
• clamping yoke/flat lug as a combination,  
Version I.  
Insulation stripping length/clamping screw/screwdriver blade  
Rated data according to IEC 60 947-7-1  
Rated voltage/current/cross-section  
15 mm/M 6/–  
–/M 6/–  
1000 V*/125 A/35 mm2  
8 kV/3  
1000 V*/125 A/35 mm2  
8 kV/3  
• flat lug, Version II.  
Two types of threading are provided  
here.  
Rated impulse voltage/pollution severity  
Further technical data  
Tightening torque range  
Nm  
3…6  
3…6  
a) screw set with lock nut  
b) with thread in busbar  
Torque setting with electric screwdriver type DMS 2  
Clampable conductor  
Solid H07V-U  
mm2  
mm2  
mm2  
mm2  
Size  
6…35  
• clamping yoke connection, Version III.  
The stripped conductor can be connec-  
ted without further preparation.  
Stranded H07V-R  
6…35  
Flexible H07V-K  
10…35  
6…35  
Flexible H07V-K and ferrule according to DIN 46 228/1  
Plug gauge according to 60 947-7-1  
Continuous current of terminal for conductor size  
Continuous current rating of cross-connection 2…5-pole  
Continuous current rating of cross-connection 6…10-pole  
Rated data according to UL/CSA  
Voltage/current/conductor size  
B 9  
Versions  
125 A/35 mm2  
125 A/35 mm2  
(QL 2) 125  
A
A
(QL 2) 125  
UL  
CSA  
Type  
KrG  
600 V/95 A/2 AWG  
600 V/115 A/2 AWG  
Voltage/current/conductor size  
600 V/110 A/6…1 AWG  
600 V/110 A/6…1 AWG  
Ordering data  
Y
Cat. No.  
Qty.  
Y
Cat. No.  
Qty.  
Version I  
Version II  
without thread  
0170020000 10  
0170320000 10  
Version IIG  
Version III  
End plate, hard paper  
Y
Cat. No.  
Qty.  
Y
Cat. No.  
Qty.  
with thread  
0205100000  
EP 1 (2)  
EP 1 (2)  
0205100000 10  
0205200000 10  
EP 1 (2)  
EP 1 (2)  
0205100000 10  
0205200000 10  
Cables with cable lugs are connected to  
SAKG terminals of Version I and to SS  
stud terminals.  
0205200000  
tropic-proof  
W
Cat. No.  
Qty.  
W
Cat. No.  
Qty.  
Fitting instructions for SAKG terminals  
0180700000, 0205300000  
0180800000, 0205400000 tropic-proof  
When tightening the clamping screw, it is  
recommended that the conductor be held  
against the direction of tightening to pre-  
vent deformation of the mounting rail and  
so as not to place the terminal foot under  
undue torsional forces.  
Partition, hard paper (thickness in mm)  
Y
Qty.  
Y
Qty.  
0151400000  
0164600000  
TW 1 (2)  
TW 1 (2)  
0151400000 10  
0164600000 10  
TW 1 (2)  
TW 1 (2)  
0151400000 10  
0164600000 10  
tropic-proof  
0177100000 B/L/H (incl. TS 32) mm  
0179900000 B/L/H (incl. TS 35) mm  
2/120/75.5  
2/120/75.5  
Cross-connection  
2-pole QL 2  
0193900000  
0407600000  
0407700000  
5
5
5
QL 2  
QL 3  
QL 4  
0193900000  
0407600000  
0407700000  
5
5
5
3-pole QL 3  
4-pole QL 4  
Cover  
AH 28  
0326660000  
5
AH 28  
DEK 5  
0326660000  
5
Cover  
Marking tags  
Print  
DEK  
Standard DEK 5  
see “Accessories”  
see “Accessories”  
To ensure shock protection following  
connections of conductors, AH covers  
can be clipped onto the terminal.  
Mounting rails, end brackets, further marking material see “Accessories”  
During conductor connection, observe clearance and creepage distances. Insert partitions if necessary.  