Feed-through terminals for TS 15
Tab connection
Solder connection
AKZ 4 SS
AKZ 4 SS
AKZ 4 S
AKZ 4 SF
U
U
U
U
Dimensions/approvals
a r
a r
a r
r
Width/length/height (mm)
with TS 15 U 6/28.5/30.5
6/28.5/30.5
6/27/30
6/27/30
Insulation stripping length/clamping screw/screwdriver blade
Rated data
9 mm/M 3/3.5 x 0.6
9 mm/M 3/3.5 x 0.6
Rated voltage*/current/cross-section
Rated impulse voltage VDE 0110/1.89/pollution severity
Further technical data
400 V/8 A/2.5/1 mm2
6 kV/3
400 V/8 A/1 mm2
6 kV/3
400 V/8 A/4/1 mm2
6 kV/3
400 V/8 A/4/1 mm2
6 kV/3
Tightening torque range
Nm
0.5…1.0
2
0.5…1.0
2
Torque setting with electric screwdriver type DMS 2
Clampable conductor
Solid H07V-U
mm2
mm2
mm2
mm2
mm2
0.5…4
1.5…4
0.5…4
0.5…4
0.5…4
0.2...4/A 3
0.5…4
1.5…4
0.5…4
0.5…4
0.5…4
0.2...4/A 3
Stranded H07V-R
Flexible H07V-K
Tab connec. 6.3 and 2.8 mm
Tab connection 2.8 mm
Flexible H07V-K and ferrule DIN 46 228/1
Flexible H07V-K and ferrule with plastic insul. collar
Max. clamping range in mm2/plug gauge acc. to IEC 60 947-1 Size
Continuous current rating of cross-connection 2-pole
Continuous current rating of cross-connection multipole
Rated data according to UL/CSA
Voltage/current/conductor size
A
A
20
20
20
20
20
20
20
20
UL
CSA
Type
KrG
150 V/10 A/22…12 AWG
300 V/10 A/24…12 AWG
150 V/10 A/22…12 AWG
300 V/10 A/24…12 AWG
U TS 15 Cat. No.
150 V/20 A/22…12 AWG
300 V/10 A/24…12 AWG
U TS 15 Cat. No.
Voltage/current/conductor size
300 V/10 A/24…12 AWG
Ordering data
U TS 15 Cat. No.
Qty.
Qty.
Qty.
U TS 15 Cat. No.
Qty.
PA
0324560000100
0362460000100
0324460000100
0158760000100
Blue PA
PA
End plate (thickness mm)
Type
Cat. No.
Qty.
Type
Cat. No.
Qty.
Type
Cat. No.
Qty.
Type
Cat. No.
Qty.
PA AP (1.5)
PA
0294460000 20 AP (1.5)
0294460000 20 AP (1.5)
0294460000 20 AP (1.5)
0294460000 20
Blue PA
HP
HP
BB
Partition (thickness mm)
PA TW (0.5)
0348260000 50 TW (0.5)
0348260000 50 TW (0.5)
0348260000 50 TW (0.5)
0348260000 50
HP
HP
Small partition
Cross-connection
Q 2
Q 3
Q 4
Q 10
0369000000 50 Q 2
0369100000 50 Q 3
0369200000 50 Q 4
0369300000 20 Q 10
0369000000 50 Q 2
0369100000 50 Q 3
0369200000 50 Q 4
0369300000 20 Q 10
0336400000 50 Q 2
0336500000 50 Q 3
0336600000 50 Q 4
0368600000 20 Q 10
0336400000 50
0336500000 50
0336600000 50
0368600000 20
Switchable cross-connection link
VL 2
0446700000 50 VL 2
0446600000 50 VH 10
0446700000 50
0446600000 50
VH 10
VL
Test plug/socket
StB
BS
VH
BS M 2.5x14 0266800000100 BS M 2.5x14 0266800000100
Plug test socket ø 2.3
StB 8.5
PS 2.3
0215700000 50 StB 8.5
0180400000 20 PS 2.3
0215700000 50 StB 8.5
0180400000 20 PS 2.3
0215700000 50 StB 8.5
0180400000 20 PS 2.3
0215700000 50
0180400000 20
PS
Cover
Insulation sleeves
IH 2.8
IH 6.3
0386060000100 IH 2.8
0386260000100
0386060000100 IH 2.8
0386060000100 IH 2.8
0386060000100
0386260000100
IH 6.3
Marking tags
Print
DEK
Mounting rails, end brackets, further marking material see “Accessories”
* Insulation sleeves are to be used for tab connections to maintain the rated voltage.
Standard DEK 6
see “Accessories”
DEK 6
see “Accessories”
DEK 6
see “Accessories”
DEK 6
see “Accessories”
162